![Grundig GD-RT-5008P User Manual Download Page 82](http://html1.mh-extra.com/html/grundig/gd-rt-5008p/gd-rt-5008p_user-manual_2272747082.webp)
82
detection, people gathering detection, fast moving detection, parking detection, unattended
baggage detection, object removal detection, audio loss exception detection, sudden
change of sound intensity detection, and defocus detection).
Note:
GD-RT-AP5004P, GD-RT-AP5008P, GD-RT-AP5016N, GD-RT-AT5016Nsupport line
crossing detection and intrusion detection of all channels, and 2-ch sudden scene
change detection. Channels with audio support audio exception detection.
GD-RT-AC3004N and GD-RT-AC3016N support 4-ch line crossing detection and
intrusion detection. GD-RT-AC3016N also support 1-ch sudden scene change
detection. Channels with audio support audio exception detection.
For the analog channels, the line crossing detection and intrusion detection conflict
with other VCA detection such as sudden scene change detection, face detection
and vehicle detection. You can only enable one function.
Step
1
Go to
Menu > Camera > VCA
.
VCA Settings
Step
2
Select a
Camera
.
Step
3
Configure the detection rules for VCA events. For details, see the step 6 in
Chapter
10.3 Line Crossing Detection
.
Step
4
Click the icon
to configure the alarm linkage actions for the VCA events.
Select
Trigger Channel
tab and select one or more channels which will start to
record when VCA alarm is triggered.
Step
5
Click
Apply
to save the settings.
Summary of Contents for GD-RT-5008P
Page 2: ......
Page 134: ...134 Set PTZ Linking Step 8 Click OK to save the settings...