![Grundig GD-RT-5008P User Manual Download Page 194](http://html1.mh-extra.com/html/grundig/gd-rt-5008p/gd-rt-5008p_user-manual_2272747194.webp)
194
Note:
Please connect the backup device to DVR before operating log export.
The log files exported to the backup device are named by exporting time, e.g.,
20110514124841logBack.txt
.
16.3 Importing/Exporting IP Camera Info
The information of added IP camera can be generated into an excel file and exported to the
local device for backup, including the IP address, manage port, password of admin, etc.
And the exported file can be edited on your PC, like adding or deleting the content, and
copy the setting to other devices by importing the excel file to it.
Step
1
Go to
Menu > Camera > Camera
> IP Camera Import/Export
.
Step
2
Click the
Export
button to export configuration files to the selected local backup
device.
Step
3
To import a configuration file, select the file from the selected backup device and
click the
Import
button. After the importing process is completed, you must reboot
the DVR.
16.4 Importing/Exporting Configuration Files
The configuration files of the DVR can be exported to local device for backup; and the
configuration files of one DVR can be imported to multiple DVR devices if they are to be
configured with the same parameters.
Step
1
Go to
Menu > Maintenance > Import/Export
.