Software
English, Revision 09, Date: 13.12.2016
42
-
by using key
the
PDO_1
operational mode can be selected. Choosing a value
between 1 and 240 the synchronous, cyclical mode can be picked. By selecting
255 the asynchronous mode is set. The two following modes are only available in
the asynchronous mode:
-
is the cycle time of the
PDO_1
transmission. If both values are 0,
PDO_1
will no be transmitted.
-
is the inhibit time of
PDO_1.
In
PDO_1
the system status and the cal-
culated distances are transmitted. The inhibt time is the shortest time
period between two periods that can be achieved.
-
by pressing
the operational mode of PDO_2 is selected. Choosing a value
between 1 and 240 the synchronous, cyclical mode can be chosen. By selecting
255 the asynchronous mode is set. The two following modes are only available in
the asynchronous mode:
-
is the time of the cycle of the
PDO_2
transmission. If both values are 0,
PDO_2
will no be transmitted.
-
is the inhibit time of
PDO_2
. In
PDO_2
the four analog antenna voltages
are transmitted. The inhibt time is the shortest time period between two
periods that can be achieved.
-
changes the so called
Heartbeat time
. A control message is sent. If the
time equals 0 no message is sent and the node guarding is active (see 4.2.3.4.3
on page 27).
-
with
the autostart is (de)activated.
-
if autostart is deactivated only the
Heartbeat
message (if activated) is
sent after turning on the device. The device is in
preoperational
state.
-
if autostart is activated the
Heartbeat
message (if activated) and the
PDOs
are sent immediately after turning on the device. The device is in
operational
state.
-
offers the option to ‘freeze‘ the output of the Y deviation for 0 to 20 telegrams,
so that e.g. the value at the time of the positioning pulse output is preserved.
-
by pressing
the order of the bytes within the
PDOs
is changed: by choosing
Lowbyte first
=
1
the low order byte of a 16bit word is transmitted first.
5.2.2.7
(D)isplay Systemstatus
Here the status bit is output (see. Table 5 on page 19). All status values that are set are
shown. As soon as a value is reset it is immediately removed from the output.
5.2.2.8
Cs(v)
For diagnosis, it is possible to start the output of the values
Code
,
U
Sum
,
U
Dif
, the states
Transponder in field
,
Code OK
,
SEGMENT-
,
Positioning pulse
(also refer
to Table 5 on page 19), number of code readings (
Read
), number of code reading fail-
ures (
N
) and in addition a telegram counter in
CSV format
(Comma Separated Values;
especially for processing text files with programs for table calculation). Data output is