Software
English, Revision 09, Date: 13.12.2016
31
5.2.1
How to start the monitor program
Depending on the currently active procedure, the monitor program is started different-
ly.
5.2.1.1
Procedure Monitor only
If the antenna is set to the procedure „Monitor only“, the monitor mode is started 10 s
after switch on. In this case no files have to be transmitted and section 5.2.1.2 may be
ignored.
5.2.1.2
Procedures 3964R/transparent
The command to switch to monitor mode should be entered directly via a PC. To do
so, start your terminal program. For the startup, as set of configuration files is neces-
sary (small text files and HyperTerminal configuration files). These files are accessible
always in the latest version from our internet server at
for download.
Start your terminal program. If you are using HyperTerminal (see section 5.1 on page
29) it can now be started directly by double clicking the respective *.ht file (
Moni-
tor19200.ht
at 19200 Bd and
Monitor38400.ht
at 38400 Bd). If necessary,
adapt the COM-port.
Following the switching on and a minimum period of 10 (respectively 26 when auto-
tune is activated) seconds, you may transfer the required *.txt file using the terminal
program. The following four files are available:
1.
Mon3964r.txt
Transfer if the system is adjusted to procedure
3964R
with “
HighByte first
“. The
file contains the characters:
0x02 0x4D 0x4F 0x4E 0x49 0x10 0x03 0x16
in hexa-decimal notation
2.
Mon6439r.txt
Transfer if the system is adjusted to procedure
3964R
with “
LowByte first
“. The
file contains the characters:
0x02 0x4F 0x4D 0x49 0x4E 0x10 0x03
0x16in hexa-decimal notation
3.
Montrans.txt
Transfer if the system is adjusted to procedure
Transparent
with “
HighByte
first
“. The file contains the characters:
0x3D 0x4D 0x4F 0x4E 0x49 0x38
in hexa-decimal notation.
4.
Transmon.txt
Transfer if the system is adjusted to procedure
Transparent
with “
LowByte
first
“. The file contains the characters:
0x3D 0x4F 0x4D 0x49 0x4E 0x38in
hexa-decimal notation