enables setting the voltage value
S
which is the threshold for releasing the position-
ing pulse output in order to eliminate false calculations due to antenna side lobes (see
releases the output of a positioning pulse only after the decoding of a Transponder.
In an interference laden environment this will avoid false positioning pulses. This filter
function reduces the maximum crossing speed, since the preset number of codes has
to be read in time before the antenna center is reached.
With
it is possible to determine the voltage threshold
S
at which the decoding and
position calculation is started, in order to suppress decoding cycles with a too weak
signal.
The duration of the positioning pulse is adjustable by pressing
within a 1 ms pat-
tern. With
it is possible to set whether with each crossing of the center axis of the
Antenna, a positioning pulse is to be generated (e. g. during a back-and-forth move-
ment directly above a Transponder). If not, only one pulse per Transponder crossing
is output. In order to release this again the voltage
S
would then have to fall under the
Threshold for Calculation-Positioning
(refer to section 5.2.2.2 on page
With
it can be chosen whether the Posipulse and the corresponding bit in the sys-
tem status are turned off after the preset time
or after the sinking of voltage
S
below
the threshold determined with
.
is used to define the behavior of the Posipulse output. With
the positioning pulse
is switched to the output, with
the bit CODE_OK is switched to the output.
enables setting a threshold for the scan coils which has to be reached in order to
activate the calculation of the lateral deviation in Y direction.
NOTE!