Components and Operation
English, Revision 09, Date: 13.12.2016
20
4.2.3.1.2
List of commands
A command telegram always consists of four bytes, including the actual command
and the parameters. When using the procedure „transparent“ it is, in addition, necs-
sary to transfer one start character and a check sum (XOR operation of all bytes in-
cluding the start character).
There are 21 predefined commands:
NOTE!
The table below is valid for 'High Byte First'-transmission. For
'Low Byte First'-transmission the order of command and parame-
ter bytes has to be changed.
The duration of 'Tune Antenna Once'-command is maximal 10
seconds for 16 tuning steps.
The monitor mode should not be used during normal operation
(e. g. from a PLC), as the following signal output is not according
to a ’transparent’ or ’3964R’ protocol but only suitable for output
on a VT52-terminal and used for the manual alteration of parame-
ters.
No.
Procedure
Start
Command
Bytes
Parameter
Bytes
Check
Sum *)
Description
1
3964R
HEX
4D
16
4F
16
4E
16
49
16
Switch to monitor mode
(description in section 5.2
„System Monitor“ on page
30)
ASCII
MO
NI
trans-
parent
HEX
3D
16
4D
16
4F
16
4E
16
49
16
38
16
ASCII
=
MO
NI
8
2
3964R
HEX
54
16
55
16
4E
16
45
16
Tune antenna once
ASCII
TU
NE
trans-
parent
HEX
3D
16
54
16
55
16
4E
16
45
16
37
16
ASCII
=
TU
NE
7
3
3964R
HEX
53
16
54
16
30
16
31
16
Set tuning value to 1
ASCII
ST
01
trans-
parent
HEX
3D
16
53
16
54
16
30
16
31
16
38
16
ASCII
=
ST
01
8
4
3964R
HEX
53
16
54
16
30
16
32
16
Set tuning value to 2
ASCII
ST
02
trans-
parent
HEX
3D
16
53
16
54
16
30
16
32
16
3B
16
ASCII
=
ST
02
;
Table 6
List of the system commands (part 1 of 4)