![Gotting HG G-98820ZA Technical Description Download Page 18](http://html1.mh-extra.com/html/gotting/hg-g-98820za/hg-g-98820za_technical-description_2247546018.webp)
Components and Operation
English, Revision 09, Date: 13.12.2016
18
Table of the data words of a telegram with 21 byte length.
Byte #
Length
Value
Type
Description
1
1 Byte
0x.0001
ASCII-061: „=“
Start sync (Default: „=“)
2,3
2 Byte
0x.0002
signed int
Y-Position: Y [mm]
within the range of -125 .. 0 .. +125
In case of an invalid value (no Transponder
detected) = 32767
4,5
2 Byte
0x.0004
signed int
Voltage generated by the transponder in the
positioning coil in [units] (Udif)
6,7,8,9
4 Byte
0x.0008
unsigned long
20 bit of the Transponder code (R/W Trans-
ponder)
10,11
2 Byte
0x.0010
unsigned int
voltage generated by the Transponder in the
reference coil in [units] (Usum)
12
1 Byte
0x.0020
unsigned char
operational voltage of the Antenna [100 mV]
13
1 Byte
0x.0040
unsigned char
power consumption [10 mA]
14
1 Byte
0x.0080
signed char
temperature within the antenna [
o
C]
15
1 Byte
0x.0100
unsigned char
number of code readings during the latest
Transponder crossing
16,17
2 Byte
0x.0200
unsigned int
receiver frequency [10 Hz]
18,19
2 Byte
0x.0400
unsigned int
transmitter frequency [10 Hz]
20,21
2 Byte
0x.0800
unsigned int
system status in binary encoding, see Table 6
on page 20
(22)
1 Byte
unsigned char
check sum, only in transparent protocol!
Table 4
Data words in a telegram with 21 byte length