![Gotting HG G-98820ZA Technical Description Download Page 55](http://html1.mh-extra.com/html/gotting/hg-g-98820za/hg-g-98820za_technical-description_2247546055.webp)
Annex
English, Revision 09, Date: 13.12.2016
55
C.2
Manufacturer specific Entries starting at 0x2000
C.3
Standardized Device Profile higher than 0x6000
Index
Subindex
Access
Content
EEProm
Refer to
0x2000
0
RO
Number of parameters
1
RW
Prog Transponder
M
2
RW
Threshold for decoding
M
3
RW
Threshold for positioning
M
4
RW
Posipulse time
M
5
RW
High nibble of RW code
M
6
RW
Number of equal codes
M
7
RW
Level to noise error
M
8
RW
Rx frequency
M
9
RW
Antenna tuning
M
a
RW
Freeze values for n tele-
grams
M
b
RW
Threshold max detection Y
M
c
RW
Config
M
0x2001
0
RO
Number of Parameter
1
RW
Node Baudrate
C
2
RW
Node ID
C
Table 24
Overview object index II
0x6000
0
RO
Number of 8 Bit Digital Inputs
Refer to
1
RO
Number of codes read
0x6100
0
RO
Number of 16 Bit Digital Inputs
1
RO
System Status
0x6120
0
RO
Number of 32 Bit Digital Inputs
1
RO
Code
Table 25
Overview object index III (part 1 of 2)