5.2.2.1
Main menu
Figure 12
Main menu of the monitor program
Each of the monitor menu windows contains important system variables in the upper
four lines (also refer to Table 20), as they also appear in the output telegram (described
in section 4.2.3.1.1 on page 17). The bottom line of the screen contains possible status
messages, e. g. if allowed values ranges were not obeyed during input.
Description of the system variables
S
Measured voltage of the sum coil in units (max. 1023)
D
Measured voltage of the positioning coil in units (max. 1023)
D_Y [mm]
Transponder position rectangular to the direction of travel in millimeters (max. ±125,
32767 when position invalid)
Code
The data bits of the Transponder in hexa decimal coding. The code is recorded as soon
as voltage
S
exceeds the
Threshold for Decoding
(refer to Figure 15 on page 37)
Read
The number of code readings per Transponder crossing (max. 255). This value is being
stored until a new Transponder code has been detected. May be deleted by noise
N
Number of reading errors per Transponder crossing. This value is stored until a new Tran-
sponder has been detected
Frx [Hz]
and
Ftx [Hz]
Display of important system frequencies for transmission and reception. These frequen-
cies are permanently monitored and are included in the system status word E (see below)
Table 20
Description of system variables (monitor program) (part 1 of 2)
S:0007 D:-007 D_Y:+32767 Code: 00000000 Read: 0: N: 0
Frx[/Hz]:66800 Ftx[/Hz]:127990
U[/mV]:24200 I[/mA]: 300 T[Grd.C]:+24 E: 0800 Noise 0
(S)erial Output
(T)ime & Code
(F)requency & Antenna tuning
Basic C(A)N-Parameters
CA(N)-Open-Parameters
(D)isplay Systemstatus
Cs(v) [38,4 KB Code,Us,Y,Tr,Co,S-,Pos,N,E,Cnt<crlf>] (abort with <a>)
display (Y)Histogram
(W)rite Transponder
(L)oad Userparameters to EEProm
(U)pdate Firmware
(1) Import User Parameter from Host to Antenna
(2) Export User Parameter from Antenna to Host
P(r)int Parameters
Software Version 98820A41.07 / Oct 31 2016 Serial Number: 110191