Electrical Power Consumption (W)
180
Condenser
Dimensions (mm)
16 × 445 × 694
Heat Transfer (W)
≥11,000
Evaporator
Cooling Capacity (W)
≥5,000
H-type Expansion Valve (Cold t)
1.5
System Cooling Capacity (W)
4,500
8.2.1.3 System Capacity
Applications
Specifications
Metric
US English
Refrigerant Lubricant (100 PG)
Refrigerant Sudden Loss
40ml *
1.34 oz *
Compressor Replacement
Note
If lubricating oil released during the refrigerant recovery is not replaced, the compressor will be damaged.
The vehicle compressor is pre-filled with 150 ml ** (5 oz **) refrigerant lubricant (100 PG).
Condenser Replacement
40 ml **
1.34 oz **
Evaporator Replacement
60 ml **
2.0 oz **
Drier Core Replacement
20 ml #
0.67 oz #
Added 100 PG oil amount should be equal to the sum of the old drier core and the prescribed amount.
Any Piping Component (Hose / Pipe or
Pipe Assembly) Replacement
30 ml **
1.0 oz **
Entire System Refrigerant Lubricating Oil
Capacity
150 ml
5.0 oz
R-134a
Refrigerant Filling Amount
600 ± 10 g
1.37 ± 0.04 b
* It may lead to the refrigerant leakage but not refrigerant oil (100 PG) loss. A serious leakage, hose broken, collision or pressure
relief valve open will lead to refrigerant sudden loss. When replacing components that lead to a large amount of refrigerant loss,
add adequate amount of lubricating oil to the components.
** If the loss of refrigerant components lubricant (100 PG) exceeds the prescribed amount, add lubricating oil according to the loss
amount.