1
2
3
Generator Harness Connector EN07
Instrument Cluster Harness Connector IP03
15 14
12
10 9 8 7 6 5 4 3 2 1
16
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
FE02-9409b
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect generator harness connector EN07.
(c)
Remove the instrument cluster, Disconnect the instrument
cluster wiring harness connector IP03.
(d)
Check the continuity between instrument cluster wiring
harness connector IP03 and generator harness connector
EN07 terminal No.1.
(e)
Measure resistance between generator harness connector
EN07 terminal No.1 and a reliable ground.
Standard Resistance Value:
Test Items
Standard Value Value
Continuity Between IP03
(13) and EN07 (1)
<1 Ω
Resistance Between EN07
(1) and A Reliable Ground
<1 Ω
(f)
Connect generator harness connector EN07.
(g)
Connect instrument cluster harness connector IP03, and
install the instrument cluster.
Is the resistance specified value?
No
Repair the faulty part. Confirm the fault has
been fixed.
Yes
Step 4
Replace the instrument cluster. Confirm the fault has been fixed.
Step 5
Check the generator regulator power supply circuit.
1
2
3
Generator Harness Connector EN07
FE02-9410b
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect generator harness connector EN07.
(c)
Measure voltage between generator harness connector
EN07 terminal No.3 and a reliable ground.
Standard Voltage: 11-14 V
(d)
Connect generator harness connector EN07.
Is the voltage specified value?
No
Generator regulator power circuit is open.
Repair the faulty part. Confirm the fault has
been fixed.
Yes
Step 6
Check the generator regulator excitation power supply.
Engine
Starting / Charging System JL4G18-D
2-567
EC718/EC718RV EC715/EC715RV 10/2009
Summary of Contents for EC715 2009
Page 4: ......
Page 330: ...Next Step 10 End 2 248 Fuel System JL4G18 D Engine EC718 EC718RV EC715 EC715RV 10 2009 ...
Page 1164: ......
Page 2008: ......