Location
Related Terminal
Standard
ACC
1-3
Conducted
ON
1-2-3
Conducted
5-6
ST
1-2
Conducted
4-5-6
If you detect there is one item that is not complying with standards, replace the ignition switch.
2.10.7.4 Ignition Relay IG1 No Power Output
Step 1
Check IG1 relay coil control power supply.
IF3
IF16
IF26
IF28
IF30
IF21
IF12
IF15
IF9
IF10
IF8
F17
F22
87
85
30
86
FE02-9002b
(a)
Turn the ignition switch to "OFF" position.
(b)
Remove the ignition relay.
(c)
Turn the ignition switch to "ON" position.
(d)
Measure voltage between ignition relay IG1 terminal No.86
and a reliable ground.
Standard Voltage: 11-14 V
Is the voltage specified value?
No
Yes
Step 2
Check IG1 relay coil ground circuit.
IF3
IF16
IF26
IF28
IF30
IF21
IF12
IF15
IF9
IF10
IF8
F17
F22
87
85
30
86
FE02-9003b
(a)
Turn the ignition switch to "OFF" position.
(b)
Remove the ignition relay.
(c)
Measure resistance between ignition relay IG1 terminal No.
85 and a reliable ground.
Standard Resistance: Less than 1 Ω
Is the resistance specified value?
No
The circuit between the relay terminal No.85
and the ground is open.
Yes
Step 3
Check the relay power input.
Engine
Ignition System JL4G18-D
2-525