Power Window Control Module (Without
Express Down) Harness Connector SO24
FE11-5404 b
(a)
Disconnect the window regulator control module harness
connector.
(b)
Test continuity between the window regulator control module
harness connector SO24 terminals No.9,10,27 and ground
with a multimeter.
Test Terminal
Continuity
SO249-Body Ground
Less than 1 Ω
SO2410-Body Ground
Less than 1 Ω
SO2427-Body Ground
Less than 1 Ω
Is the resistance specified value?
Yes
No
Step 8
Repair the window regulator control module and the ground open circuit.
(a)
Repair the open circuit between the window regulator control
module harness connector SO24 terminals No.9,10,27 and
ground.
Is the window regulator working properly?
Yes
System normal
No
Step 9
Replace the window regulator control module.
(a)
Replace the window regulator control module. Refer to
Window Regulator Module Replacement (If
.
(b)
Confirm the repair completed.
Next
Step 10
System normal.
11.5.7.7 Left Front Window Regulator Inoperative (Without Window Express Down Function)
Schematic:
All Electric Windows Inoperative (Without Window Express Down Function)
.
Diagnostic Steps:
Step 1
Check the left front window lift switch ground circuit.
11-170