Asset Light 

Asset Pro

 

 

 

 

 

 

 

 

 

 

 
 
 
   

 

 AddSecure 
 Asset 

 

Installation Guide 

Summary of Contents for Asset Light

Page 1: ...Version 2 3 2017 01 26 PEP FB Asset Light Asset Pro AddSecure Asset Installation Guide ...

Page 2: ... LED 7 6 Final test 7 7 Carrier Transicold 8 7 1 Datalogger Datacold 500 600 and EuroScan X2 8 7 1 1 Mounting 8 7 1 2 Connection 8 7 1 3 Ignition Connection 9 7 1 4 Configuration of datacold 500 600 and EuroScanX2 9 7 1 5 System configuration 9 8 ThermoKing 10 8 1 Datalogger DAS SR2 CargoWatch 10 8 1 1 Serial RS 232 connection to CargoWatch 10 8 1 2 Ignition Connection 10 8 1 3 Configuration of da...

Page 3: ...sistant auto fuse on the white wire to permanent supply Place the fuse as close to the power source as possible to protect the vehicle To obtain a water proof installation mount the supplied four locking devices Mount the unit on a suitable place where it is protected from water Never clean the unit with a high pressure cleaner The wire output must face downwards When attaching the power multi con...

Page 4: ...temperature sensor 10 Blue Not used Digital Output 11 Grey Not used Digital Input 12 Brown Terminal 15 ignition Ignition has to be connected if there is no ignition signal in the vehicle connect the cable to terminal 30 24 Volt 13 Black Terminal 31 ground Battery minus terminal 14 White Terminal 30 24 Volt Constant supply between 10 Volt to 60 Volt ...

Page 5: ...Used for ThermoKing Carrier 3 Green RX RS 232 Used for ThermoKing Carrier 4 Black Whit e CAN Not used 5 Red White CAN Not used 10 Blue Outout Not used 11 Grey Input 2 Not used 12 Brown Terminal 15 ignition Ignition has to be connected if there is no ignition signal in the vehicle connect the cable to terminal 30 24 Volt 13 Black Terminal 31 ground Battery minus terminal 14 White Terminal 30 24 Vol...

Page 6: ...e The cable is with silicone outer jacket and Teflon inner jackets so it is durable in high and low temperatures The capacity between wires must not be higher than 10 15 pF per meter Total length added for all sensors is maximum 20 meters 3 2 Temperature sensor PRO version only Where to mount the temperature sensor Possible places to mount the temperature sensor At the air intake of the cooling sy...

Page 7: ...d they must be parallel mounted White core to white core and brown core to brown core Wires may be extended All soldering must be isolated 4 Wireless Sensors When mounting wireless sensors the Asset unit is not allowed to be placed in the trucks cabin The Asset unit should be mounted on the trailer or cargo unit ...

Page 8: ...Asset unit the range will vary e g the Asset unit cannot be mounted in the trucks cabin and communicate with the sensor Note Write down the serial number of the sensor located on the back of the sensor A wireless temperature sensor consists of only one part the Sensor Depending on materials between and around the sensor and Asset unit the range will vary e g the Asset unit cannot be mounted in the...

Page 9: ...alid time or not on unit All values stated after are examples ON OFF button When the unit is off it must not be connected to a power source Press button for 5 seconds till yellow lamp starts to flash differently Release the button and press it briefly again Turn off the unit Yellow System service Constant light System starts 1 flash System is on but not connected to GSM data 2 fast flashes System ...

Page 10: ...ld 7 1 Datalogger Datacold 500 600 and EuroScan X2 7 1 1 Mounting The Asset Pro can be mounted on the rear of the datalogger 7 1 2 Connection It mush flush with the edges Make sure that there is room for the printer cable ...

Page 11: ...ot used the brown wire must be connected to the white wire Datacold 12 volt 7 1 4 Configuration of datacold 500 600 and EuroScanX2 The configuration of the datacold must be done before the Lommy works Hold the green button for 2 seconds The display shows Enter PIN Factory code is 1111 press 4 times the blue Select menu 11 with the arrow keys Datacold 500 Com 1 should be Thirdparty Datacold 600 Com...

Page 12: ...ht It will then show if the trailer is connected to a truck with ignition on Light turned on Trailer and datalogger has separated ground Remember to mount the 1 kohm resistor R2 On trucks the ground is normally common and the resistor is not needed Can also be connected to the ignition of the refrigeration unit and used to indicate is the cooler is running If this option is not used the brown wire...

Page 13: ...11 8 2 i Box ...

Page 14: ...Datalogger To connect to a HUK you will need a male DB9 connector Power is connected as usual PINOUT Asset DB9 Green 2 Orange 3 Black 5 Jumper between 7 8 10 System configuration See the document Asset configuration AddSecure ...