![GE UR Series C70 Instruction Manual Download Page 34](http://html.mh-extra.com/html/ge/ur-series-c70/ur-series-c70_instruction-manual_130387034.webp)
2-4
C70 Capacitor Bank Protection and Control System
GE Multilin
2.1 INTRODUCTION
2 PRODUCT DESCRIPTION
2
b) ORDER CODES WITH TRADITIONAL CTS AND VTS
The order codes for the horizontal mount units with standard CTs and VTs are shown below.
Table 2–3: C70 ORDER CODES (HORIZONTAL UNITS WITH TRADITIONAL CTS AND VTS)
C70
-
*
**
-
*
*
*
- F
**
- H
**
- M
**
- P
**
- U
**
-
W/X
**
Full Size Horizontal Mount
BASE UNIT
C70
|
|
|
|
|
|
|
|
|
|
|
Base Unit
CPU
E
|
|
|
|
|
|
|
|
|
|
RS485 and RS485
G
|
|
|
|
|
|
|
|
|
|
RS485 and multi-mode ST 10Base-F
H
|
|
|
|
|
|
|
|
|
|
RS485 and multi-mode ST redundant 10Base-F
J
|
|
|
|
|
|
|
|
|
|
RS485 and multi-mode ST 100Base-FX
N
|
|
|
|
|
|
|
|
|
|
RS485 and 10/100Base-T
S
|
|
|
|
|
|
|
|
|
|
RS485 and managed six-port Ethernet switch
SOFTWARE
00
|
|
|
|
|
|
|
|
|
No software options
03
|
|
|
|
|
|
|
|
|
IEC 61850; not available for type E CPUs
12
|
|
|
|
|
|
|
|
|
Enhanced capacitor bank control (time and date, capacitor control supervision, automatic voltage regulator)
13
|
|
|
|
|
|
|
|
|
Enhanced capacitor bank control and IEC 61850; not available for type E CPUs
MOUNT/COATING
H
|
|
|
|
|
|
|
|
Horizontal (19” rack)
A
|
|
|
|
|
|
|
|
Horizontal (19” rack) with harsh environmental coating
FACEPLATE/ DISPLAY
C
|
|
|
|
|
|
|
English display
P
|
|
|
|
|
|
|
English display with 4 small and 12 large programmable pushbuttons
K
|
|
|
|
|
|
|
Enhanced front panel with English display
M
|
|
|
|
|
|
|
Enhanced front panel with French display
Q
|
|
|
|
|
|
|
Enhanced front panel with Russian display
U
|
|
|
|
|
|
|
Enhanced front panel with Chinese display
L
|
|
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
N
|
|
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
T
|
|
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
V
|
|
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
POWER SUPPLY
H
|
|
|
|
|
|
125 / 250 V AC/DC power supply
L
|
|
|
|
|
|
24 to 48 V (DC only) power supply
CT/VT MODULES
8L
|
8L
|
8L
|
Standard 4CT/4VT with enhanced diagnostics
8N
|
8N
|
8N
|
Standard 8CT with enhanced diagnostics
8V
|
8V
|
8V
|
Standard 8VT with enhanced diagnostics
DIGITAL INPUTS/OUTPUTS
XX
XX
XX
No Module
6A
6A
6A
6A
6A
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
6B
6B
6B
6B
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
6C
6C
6C
6C
8 Form-C outputs
6D
6D
6D
6D
6D
16 digital inputs
6E
6E
6E
6E
6E
4 Form-C outputs, 8 digital inputs
6F
6F
6F
6F
6F
8 Fast Form-C outputs
6G
6G
6G
6G
6G
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6H
6H
6H
6H
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
6K
6K
6K
6K
4 Form-C and 4 Fast Form-C outputs
6L
6L
6L
6L
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M
6M
6M
6M
6M
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N
6N
6N
6N
6N
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6P
6P
6P
6P
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
6R
6R
6R
6R
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
6S
6S
6S
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
6T
6T
6T
6T
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6U
6U
6U
6U
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
6V
6V
6V
6V
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 digital inputs
TRANSDUCER INPUTS/OUTPUTS (maximum of 3 per unit)
5A
5A
5A
5A
5A
4 dcmA inputs, 4 dcmA outputs (only one 5A module is allowed)
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
2G
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
|
2S
Six-port managed Ethernet switch with high voltage power supply (110 to 250 V DC / 100 to 240 V AC)
|
2T
Six-port managed Ethernet switch with low voltage power supply (48 V DC)
77
77
IEEE C37.94, 820 nm, multimode, LED, 2 Channels
7H
7H
820 nm, multi-mode, LED, 2 Channels
7I
7I
1300 nm, multi-mode, LED, 2 Channels
7S
7S
G.703, 2 Channels
7W
7W
RS422, 2 Channels
Summary of Contents for UR Series C70
Page 2: ......
Page 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Page 344: ...5 220 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 586: ...D 10 C70 Capacitor Bank Protection and Control System GE Multilin D 1 OVERVIEW APPENDIXD D ...