6-38
MM2 Motor Manager 2
GE Power Management
6.5 MEMORY MAP
6 COMMUNICATIONS
6
PROG.
INPUTS
continued
44554
4553 11C9 Interlock 10 Switch Type
0-1
1
-
F30
0 = N.O.
44555
4554 11CA Ground Alarm Delay on Start
1-60
1
s
F1
10
44556
4555 11CB Ground Trip Delay on Start
0-100
1
s
F1
10
44557
4556 11CC ...Reserved...
...
...
...
...
...
↓
↓
↓
↓
↓
↓
↓
↓
↓
44560
4559 11CF ...Reserved...
...
...
...
...
...
PROCESS
INTER-
LOCK
NAMES
44561
4560 11D0 Process Intlk E Name chars 1 and 2
32-127
1
ASCII
F10
‘PR’
44562
4561 11D1 Process Intlk E Name chars 3 and 4
32-127
1
ASCII
F10
‘OC’
44563
4562 11D2 Process Intlk E Name chars 5 and 6
32-127
1
ASCII
F10
‘ES’
44564
4563 11D3 Process Intlk E Name chars 7 and 8
32-127
1
ASCII
F10
‘S ‘
44565
4564 11D4 Process Intlk E Name chars 9 & 10
32-127
1
ASCII
F10
‘IN’
44566
4565 11D5 Process Intlk E Name chars 11 & 12
32-127
1
ASCII
F10
‘TE’
44567
4566 11D6 Process Intlk E Name chars 13 & 14
32-127
1
ASCII
F10
‘RL’
44568
4567 11D7 Process Intlk E Name chars 15 & 16
32-127
1
ASCII
F10
‘OC’
44569
4568 11D8 Process Intlk E Name chars 17 & 18
32-127
1
ASCII
F10
‘K ‘
44570
4569 11D9 Process Intlk E Name chars 19 & 20
32-127
1
ASCII
F10
‘E ‘
44571
4570 11DA ...Reserved...
...
...
...
...
...
↓
↓
↓
↓
↓
↓
↓
↓
↓
44576
4575 11DF ...Reserved...
...
...
...
...
...
44577
4576 11E0 Process Intlk F Name chars 1 and 2
32-127
1
ASCII
F10
‘PR’
44578
4577 11E1 Process Intlk F Name chars 3 and 4
32-127
1
ASCII
F10
‘OC’
44579
4578 11E2 Process Intlk F Name chars 5 and 6
32-127
1
ASCII
F10
‘ES’
44580
4579 11E3 Process Intlk F Name chars 7 and 8
32-127
1
ASCII
F10
‘S ‘
44581
4580 11E4 Process Intlk F Name chars 9 & 10
32-127
1
ASCII
F10
‘IN’
44582
4581 11E5 Process Intlk F Name chars 11 & 12
32-127
1
ASCII
F10
‘TE’
44583
4582 11E6 Process Intlk F Name chars 13 & 14
32-127
1
ASCII
F10
‘RL’
44584
4583 11E7 Process Intlk F Name chars 15 & 16
32-127
1
ASCII
F10
‘OC’
44585
4584 11E8 Process Intlk F Name chars 17 & 18
32-127
1
ASCII
F10
‘K ‘
44586
4585 11E9 Process Intlk F Name chars 19 & 20
32-127
1
ASCII
F10
‘F ‘
44587
4586 11EA ...Reserved...
...
...
...
...
...
↓
↓
↓
↓
↓
↓
↓
↓
↓
44592
4591 11EF ...Reserved...
...
...
...
...
...
44593
4592 11F0 Process Intlk G Name chars 1 and 2
32-127
1
ASCII
F10
‘PR’
44594
4593 11F1 Process Intlk G Name chars 3 and 4
32-127
1
ASCII
F10
‘OC’
44595
4594 11F2 Process Intlk G Name chars 5 and 6
32-127
1
ASCII
F10
‘ES’
Table 6–12: MODBUS MEMORY MAP (Sheet 19 of 21)
GROUP
MOD-
ICON
REGISTER
ADDRESS
DESCRIPTION
REGISTE
R VALUE
RANGE
STEP
VALUE
UNITS
AND
SCALE
FOR-
MAT
FACTORY
DEFAULT
VALUE
(CONVERTED)
DEC
HEX
Notes: * – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
Summary of Contents for MOTOR MANAGER 2
Page 2: ......
Page 4: ......
Page 34: ...3 8 MM2 Motor Manager 2 GE Power Management 3 3 THEORY OF OPERATION 3 HARDWARE 3 ...
Page 80: ...5 12 MM2 Motor Manager 2 GE Power Management 5 5 A4 STATISTICS 5 ACTUAL VALUES 5 ...
Page 188: ...9 40 MM2 Motor Manager 2 GE Power Management 9 13 SOFT STARTER 9 STARTER TYPES 9 ...
Page 212: ...E 4 MM2 Motor Manager 2 GE Power Management E 1 CT ISOLATION APPENDIXE E ...
Page 220: ...iv MM2 Motor Manager 2 GE Power Management INDEX ...