B-54
L30 Line Current Differential System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
B22A
...Repeated for Received Analog 14
B22C
...Repeated for Received Analog 15
B22E
...Repeated for Received Analog 16
B230
...Repeated for Received Analog 17
B232
...Repeated for Received Analog 18
B234
...Repeated for Received Analog 19
B236
...Repeated for Received Analog 20
B238
...Repeated for Received Analog 21
B23A
...Repeated for Received Analog 22
B23C
...Repeated for Received Analog 23
B23E
...Repeated for Received Analog 24
B240
...Repeated for Received Analog 25
B242
...Repeated for Received Analog 26
B244
...Repeated for Received Analog 27
B246
...Repeated for Received Analog 28
B248
...Repeated for Received Analog 29
B24A
...Repeated for Received Analog 30
B24C
...Repeated for Received Analog 31
B24E
...Repeated for Received Analog 32
IEC 61850 Configurable Report Settings (Read/Write Setting)
B290
IEC 61850 configurable reports dataset items (64 items)
0 to 848
---
1
F615
0 (None)
IEC 61850 XSWI Configuration (Read/Write Setting) (24 modules)
B370
Flexlogic Operand for IEC 61850 XSWI.ST.Loc Status
0 to 4294967295
---
1
F300
0
IEC 61850 XSWI Configuration (Read/Write Command) (24 modules)
B372
Command to Clear XSWI OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B400
Number of Status Indications in GGIO1
8 to 128
---
8
F001
8
B402
IEC 61850 GGIO1 Indication FlexLogic operands (128
items)
0 to 4294967295
---
1
F300
0
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function
0 to 1
---
1
F102
0 (None)
B5A1
IEC 61850 Configurable GOOSE ID
---
---
---
F209
“GOOSEOut_x_”
B5C2
Configurable GOOSE Destination MAC Address
---
---
---
F072
0
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
0 to 7
---
1
F001
4
B5C6
IEC 61850 Configurable GOOSE VLAN ID
0 to 4095
---
1
F001
0
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
0 to 16383
---
1
F001
0
B5C8
IEC 61850 Configurable GOOSE ConfRev
1 to 4294967295
---
1
F003
1
B5CA
IEC 61850 Configurable GOOSE Retransmission Curve
0 to 3
---
1
F611
3 (Relaxed)
B5CB
Configurable GOOSE dataset items for transmission
(64 items)
0 to 542
---
1
F616
0 (None)
B60B
...Repeated for Module 2
B676
...Repeated for Module 3
B6E1
...Repeated for Module 4
B74C
...Repeated for Module 5
B7B7
...Repeated for Module 6
B822
...Repeated for Module 7
B88D
...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)
B900
Configurable GOOSE dataset items for reception
(32 items)
0 to 197
---
1
F233
0 (None)
B920
...Repeated for Module 2
B940
...Repeated for Module 3
B960
...Repeated for Module 4
B980
...Repeated for Module 5
B9A0
...Repeated for Module 6
Table B–9: MODBUS MEMORY MAP (Sheet 46 of 61)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for L30
Page 10: ...x L30 Line Current Differential System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 L30 Line Current Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 370: ...5 244 L30 Line Current Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 464: ...A 10 L30 Line Current Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 600: ...C 30 L30 Line Current Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 610: ...D 10 L30 Line Current Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 622: ...E 12 L30 Line Current Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 634: ...F 12 L30 Line Current Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...
Page 644: ...x L30 Line Current Differential System GE Multilin INDEX ...