GE Multilin
L30 Line Current Differential System
B-33
APPENDIX B
B.4 MEMORY MAPPING
B
4E0C
Raw Field Data AC5 Mag
0 to 0.001
A/V
0.001
F003
0
4E0E
Raw Field Data AC5 Angle
0 to 0.01
degree
0.1
F002
0
4E0F
Raw Field Data AC6 Mag
0 to 0.001
A/V
0.001
F003
0
4E11
Raw Field Data AC6 Angle
0 to 0.01
degree
0.1
F002
0
4E12
Raw Field Data AC7 Mag
0 to 0.001
A/V
0.001
F003
0
4E14
Raw Field Data AC7 Angle
0 to 0.01
degree
0.1
F002
0
4E15
Raw Field Data AC8 Mag
0 to 0.001
A/V
0.001
F003
0
4E17
Raw Field Data AC8 Angle
0 to 0.01
degree
0.1
F002
0
4E18
Raw Field Data DC1
0 to 0.001
V
0.001
F002
0
4E19
Raw Field Data DC2
0 to 0.001
V
0.001
F002
0
4E1A
Raw Field Data DC3
0 to 0.001
V
0.001
F002
0
4E1B
Raw Field Data FCI States (2 items)
0 to 1
---
1
F500
0
4E1D
Raw Field Data SI States
0 to 1
---
1
F500
0
4E1E
Raw Field Data SI Test States
0 to 1
---
1
F500
0
4E1F
Raw Field Data Brick ADC Temperature
0 to 1
degree
1
F002
0
4E20
Raw Field Data Brick Transceiver Temperature
0 to 1
degree
1
F002
0
4E21
Raw Field Data Brick Transceiver Voltage
0 to 0.01
V
0.01
F001
0
4E22
Raw Field Data Brick Transceiver Current
0 to 1
mA
1
F001
0
4E23
Raw Field Data Brick Tx Power
0 to 0.01
dBm
0.1
F002
0
4E24
Raw Field Data Brick Rx Power
0 to 0.1
dBm
0.1
F002
0
4E25
Raw Field Data Brick Diagnostics (2 items)
0 to 65535
---
1
F500
0
4E27
Raw Field Data Local Transceiver Temperature
0 to 1
degree
1
F002
0
4E28
Raw Field Data Local Transceiver Voltage
0 to 0.01
V
0.01
F001
0
4E29
Raw Field Data Local Transceiver Current
0 to 1
mA
1
F001
0
4E2A
Raw Field Data Local Tx Power
0 to 0.1
dBm
0.1
F002
0
4E2B
Raw Field Data Local Rx Power
0 to 0.1
dBm
0.1
F002
0
4E2C
Repeated for module number 2
4E58
Repeated for module number 3
4E84
Repeated for module number 4
4E80
Repeated for module number 5
4EDC
Repeated for module number 6
4F08
Repeated for module number 7
4F34
Repeated for module number 8
Flexlogic (Read/Write Setting)
5000
FlexLogic Entry (512 items)
0 to 4294967295
---
1
F300
2097152
RTD Inputs (Read/Write Setting) (48 modules)
5400
RTD Input 1 Function
0 to 1
---
1
F102
0 (Disabled)
5401
RTD Input 1 ID
---
---
---
F205
“RTD Ip 1“
5407
RTD Input 1 Type
0 to 3
---
1
F174
0 (100 ohm
Platinum)
5414
...Repeated for RTD Input 2
5428
...Repeated for RTD Input 3
543C
...Repeated for RTD Input 4
5450
...Repeated for RTD Input 5
5464
...Repeated for RTD Input 6
5478
...Repeated for RTD Input 7
548C
...Repeated for RTD Input 8
54A0
...Repeated for RTD Input 9
54B4
...Repeated for RTD Input 10
54C8
...Repeated for RTD Input 11
54DC
...Repeated for RTD Input 12
54F0
...Repeated for RTD Input 13
5404
...Repeated for RTD Input 14
5518
...Repeated for RTD Input 15
Table B–9: MODBUS MEMORY MAP (Sheet 25 of 61)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for L30
Page 10: ...x L30 Line Current Differential System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 L30 Line Current Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 370: ...5 244 L30 Line Current Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 464: ...A 10 L30 Line Current Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 600: ...C 30 L30 Line Current Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 610: ...D 10 L30 Line Current Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 622: ...E 12 L30 Line Current Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 634: ...F 12 L30 Line Current Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...