3. VERTICAL MODE
3-5
3.4
Setting the Vertical Bearing Mark, Auto Train
3.4.1
Setting the vertical bearing mark
1. Use the trackball to place the trackball marker at the desired location in the
horizontal display.
2. Press the [V1] or [V2] key.
For example, press the [V1] key. Then, the Vertical 1 display appears, and the
vertical bearing marker is displayed in the horizontal display, with “V” at the tip of
the marker. If both vertical displays are activated, “1” or “2” is inscribed at the tip
of a vertical bearing marker.
3.4.2 Auto
train
You may scan the vertical bearing mark in the sector of OFF,
±
12
°
,
±
24
°
and
±
36
°
.
1. Press and hold down the [AUTO TRAIN] key while pressing the [V1] or [V2]
key to choose auto train sector desired. Selected sector appears in large
characters for five seconds for your confirmation. The auto train starts.
Vertical bearing
mark
Auto train mark
1
Auto train sector
Figure 3-6 Auto train
2. To quit the auto train, set OFF at the step 1.