Bushing
Shaft
Pick Roller Assembly
6.
Remove the shaft of the pick roller from the ScanSnap.
Lift the left side of the shaft slightly (about 5 mm), move it toward the left, and then lift it upward
to pull it out.
Pick Roller Assembly
Shaft
ATTENTION
There may be paper dust around the pick roller assembly.
Wipe off the paper dust with a cloth moistened with Cleaner F1. Not doing so may cause image
faults.
Do not use water, mild detergent, or aerosol spray.
7.
Remove the pick roller assembly from the shaft.
→ While lifting the retaining clip of the pick roller assembly, pull out the shaft.
Pick Roller Assembly
Shaft
Replacing Consumables for S1300i