Replacing the Pick Roller Assembly (S1300i)
Replace the pick roller assembly in the following procedure:
1.
Unplug the power connection cable (power cable or USB bus power cable)
from the power supply source (AC outlet or computer).
2.
Remove any documents from the ADF paper chute (cover).
3.
Pull the ADF release tab towards you to open the ADF top section.
ADF Paper Chute (Cover)
ADF Release Tab
ADF Top Section
4.
Remove the sheet guide.
While holding the squeeze clip on the right end and pressing it inward, lift the sheet guide to
remove it.
Squeeze
Clip
Squeeze
Clip
Sheet Guide
5.
Turn the bushing that is on the left.
Replacing Consumables for S1300i