CX250 S2
Upgrade and Maintenance Manual
263
Appendix
11.3
Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê
Shut down the server as described in section
"Shutting down the server
node" on page 45
.
Ê
Take the system down to its minimum startup configuration.
Ê
Connect a keyboard, mouse and display to the server.
Ê
Switch on the server as described in section
"Switching on the server node"
on page 64
.
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
Field Replaceable Units (FRU)
Component
Notes and reference
System board
no TPM or expansion cards installed
CPU0 with CPU heat sink
1 memory module
installed in slot A1 or C1, see section
"Memory
sequence" on page 172
1 Power supply unit
Table 13: Minimum startup configuration - components
Cable
Notes and reference
2 SATA cables
Table 14: Minimum startup configuration - cables
Summary of Contents for Primergy CX250 S2
Page 6: ...Upgrade and Maintenance Manual CX250 S2 ...
Page 16: ...16 Upgrade and Maintenance Manual CX250 S2 ...
Page 20: ...20 Upgrade and Maintenance Manual CX250 S2 Introduction ...
Page 30: ...30 Upgrade and Maintenance Manual CX250 S2 Before you start ...
Page 44: ...44 Upgrade and Maintenance Manual CX250 S2 Important information ...
Page 184: ...184 Upgrade and Maintenance Manual CX250 S2 Main memory ...
Page 244: ...244 Upgrade and Maintenance Manual CX250 S2 System board and components ...
Page 254: ...254 Upgrade and Maintenance Manual CX250 S2 Cabling ...