72
Upgrade and Maintenance Manual
CX250
S2
Basic software procedures
BMC recovery procedure
I
For the Japanese market, follow the instructions provided separately.
I
The BMC flash procedure will take some time. It can be up to 5 minutes
until a screen is shown on the screen.
Ê
Prepare a bootable USB stick including the bootable BMC firmware update
image.
Ê
Ensure that the server has been shut down and disconnected from the
mains as described in section
"Shutting down the server node" on page 45
.
Ê
Connect the USB stick to the USB port.
I
Ensure that only the USB device with the BMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê
Ensure that BMC jumper is connected.
Ê
The Power ON LED will be reverse in BMC Recovery Mode.
System off: PW LED green
System on: PW LED off
Blue ID LED is always lit.
Ê
Press the Power On / Off button. The system starts the POST process.
Ê
The system will detect the USB stick.
Ê
The system boots from DOS and you have to change to that directory of the
USB stick in which the flash files are contained.
Ê
Execute the
DOS.BAT
file.
V
CAUTION!
Do not interrupt the BMC upgrade process after it has started. If the
process is interrupted, the BMC BIOS may be permanently corrupted.
I
If the BMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê
Shut down the server by pressing the power On / Off button.
Ê
Disconnect the server from the mains to exit the BMC recovery state.
Ê
Ensure that BMC jumper is disconnected.
Summary of Contents for Primergy CX250 S2
Page 6: ...Upgrade and Maintenance Manual CX250 S2 ...
Page 16: ...16 Upgrade and Maintenance Manual CX250 S2 ...
Page 20: ...20 Upgrade and Maintenance Manual CX250 S2 Introduction ...
Page 30: ...30 Upgrade and Maintenance Manual CX250 S2 Before you start ...
Page 44: ...44 Upgrade and Maintenance Manual CX250 S2 Important information ...
Page 184: ...184 Upgrade and Maintenance Manual CX250 S2 Main memory ...
Page 244: ...244 Upgrade and Maintenance Manual CX250 S2 System board and components ...
Page 254: ...254 Upgrade and Maintenance Manual CX250 S2 Cabling ...