206
Upgrade and Maintenance Manual
CX250
S2
Processors
Figure 119: Installing the heat sink CPU1 (B)
I
To avoid inclining of the heat sink carefully press on the middle of the
heat sink.
Ê
Fasten the four captive screws on the heat sink in a crossover pattern
according to the numbering (screw torque: 1.0 Nm, not applicable for the
Japanese market).
8.2.8
Concluding steps
Perform the following steps:
Ê
"Installing the server node in the server enclosure" on page 63
Ê
"Updating or recovering the system board BIOS and BMC" on page 67
(if
applicable)
Ê
"Switching on the server node" on page 64
Ê
"Enabling boot watchdog functionality" on page 74