23.3 Device Connection Setting
23-9
•
n + 7 (ENT2) entry information 2
The entry mode window number where a write operation was executed is written.
The relationship between the window number and base and the window number and overlap is shown in the following
table.
- In case of using the entry mode for the table data display
The line number and the column number will be output to the address n + 1 and the block number to the address
n + 2 of the “Info. Output Memory,” when the bit No. 12 of “Command Memory” in the [Entry] dialog is ON [1]. In only
this case, therefore, the window number cannot be referred because the block number is output to the address n + 7
(ENT2) of the write area.
•
n + 8 (GREPNS) global response
A response is written when a global port number is used in 1 : n communication. The contents of a response are shown
in the following table. For details on the global port number, see page 23-15.
•
n + 9 to n + 15
System reserved
Calendar
Select a device from which the calendar data is read without using the S8 series’ built-in clock. For more information on the
built-in clock, refer to the S8 Series Reference Manual.
•
PLC1 to 2
Calendar data is read from the selected device.
The calendar data will be updated when:
- The power is turned on.
- STOP
→
RUN
- The date changes.
- At the leading edge of a bit (0
→
1) in the calendar memory in the reading area
Initial screen
Set the number of the screen to be displayed when power to the S8 series is turned on.
GD-80 Compatible
This setting is not valid because the GD-80 series cannot be used for universal serial communication.
Window No.
Contents
0
Base entry mode
1
Overlap 0 entry mode
2
Overlap 1 entry mode
3
Overlap 2 entry mode
Memory Contents
Contents
0000
Global command not received
0100
ACK
Others
Identical to NAK code (see page 23-16).
Summary of Contents for Monitouch S8 series
Page 1: ...Connection Manual...
Page 3: ......
Page 5: ......
Page 17: ......
Page 19: ......
Page 43: ...1 24 1 Overview...
Page 44: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 45: ......
Page 56: ...3 1 PLC Connection 3 Automation Direct...
Page 57: ......
Page 66: ...4 EATON Cutler Hammer 4 1 PLC Connection...
Page 67: ......
Page 71: ...4 4 4 EATON Cutler Hammer Please use this page freely...
Page 72: ...5 FANUC 5 1 PLC Connection...
Page 73: ......
Page 78: ...6 FATEK AUTOMATION 6 1 PLC Connection...
Page 79: ......
Page 84: ...7 Fuji Electric 7 1 PLC Connection 7 2 Temperature Controller Servo Inverter Connection...
Page 85: ......
Page 158: ...8 IAI 8 1 Temperature Controller Servo Inverter Connection...
Page 159: ......
Page 173: ...8 14 8 IAI Please use this page freely...
Page 174: ...9 KEYENCE 9 1 PLC Connection...
Page 175: ......
Page 186: ...10 LS 10 1 PLC Connection...
Page 187: ......
Page 197: ......
Page 223: ...11 26 11 MITSUBISHI ELECTRIC Please use this page freely...
Page 224: ...12 OMRON 12 1 PLC Connection 12 2 Temperature Controller Servo Inverter Connection...
Page 225: ......
Page 244: ...13 Panasonic Electric Works 13 1 PLC Connection...
Page 245: ......
Page 253: ...13 8 13 Panasonic Electric Works Please use this page freely...
Page 254: ...14 RKC 14 1 Temperature Controller Servo Inverter Connection...
Page 255: ......
Page 264: ...15 SAIA 15 1 PLC Connection...
Page 265: ......
Page 269: ...15 4 15 SAIA Please use this page freely...
Page 270: ...16 1 PLC Connection 16 Siemens...
Page 271: ......
Page 276: ...17 1 Temperature Controller Servo Inverter Connection 17 Yamatake...
Page 277: ......
Page 285: ...17 8 17 Yamatake Please use this page freely...
Page 286: ...18 Yaskawa Electric 18 1 PLC Connection...
Page 287: ......
Page 295: ...18 8 18 Yaskawa Electric Please use this page freely...
Page 296: ...19 1 PLC Connection 19 2 Temperature Controller Servo Inverter Connection 19 Yokogawa Electric...
Page 297: ......
Page 307: ...19 10 19 Yokogawa Electric Please use this page freely...
Page 308: ...20 1 PLC Connection 20 MODBUS...
Page 309: ......
Page 314: ...21 1 Barcode Reader Connection 21 Barcode Reader...
Page 315: ......
Page 320: ...22 1 V Link 22 2 Modbus RTU Slave Communication 22 Slave Communication Function...
Page 321: ......
Page 333: ...22 12 22 Slave Communication Function Please use this page freely...
Page 335: ......
Page 367: ...23 32 23 Universal Serial Communication Please use this page freely...
Page 369: ......
Page 403: ...App4 6 Please use this page freely...