background image

© 2018 UTC Fire & Security Americas Corporation, Inc. 

1 / 7 

 P/N 466-5438 • REV A • ISS 16OCT18 

Simon 5" TouchScreen Version 2 
Installation Guide 

Description

The Simon 5” TouchScreen model 60-924-RF-TS5-2 features 
a color 5-inch LCD screen with a graphical user interface 
designed to control basic functionality of the Simon XT (v1.3 or 
later), Simon XTi, and Simon XTi-5 control panels. Up to four 
touch screens can be learned (programmed) into each Simon 
XT, XTi, or XTi-5 panel.  Note the TouchScreen is optimized to 
work with the latest features in the Simon XTi-5 Version 2. 

The touch screen provides a convenient option for the 
following system operations: 

x

 

Arm the system (doors, windows, and motion sensors). 

x

 

Disarm the system. 

x

 

Activate a panic alarm to call the central monitoring station 
in a nonmedical emergency. 

x

 Check 

system 

status. 

x

 

Turn system controlled lights on or off (depending on your 
system configuration). 

x

 

Lock and unlock system-controlled door locks (depending 
on your system configuration). 

x

 

Open and close system-controlled garage doors 
(depending on your system configuration; XTi-5 Version 2 
Panel only). 

x

 

Hear voice feedback of the status of the Simon XT, XTi, 
XTi-5, or XTi-5 V2 control panel. 

x

 

Customize color and fonts matching the interactive service 
on the mobile phone (Xti-5 Panel Version 2 only). 

Safety Information 

IMPORTANT SAFETY INFORMATION; READ ENCLOSED 
WARNINGS AND SAFETY INFORMATION. 

 WARNING: CHOKING HAZARD.

 The product accessory bag 

contains items that could be choking hazards. Please 
keep away from small children.  

 WARNING:

Disconnect panel power before servicing.

 CAUTION:

Use static electricity precautions when handling 
electronic components.

 CAUTION:

Only the cable provided with the device can be used to 
provide power.  

Installation Guidelines 

Use the following guidelines when adding this touch screen to 
the Simon XT, XTi, XTi-5, or XTi-5 V2 system: 

x

 

Power up and learn the touch screen into the panel and 
verify its operation before mounting it to its permanent wall 
or desktop location. 

x

 

The touch screen should be the last sensor programmed 
(learned) into the panel. Doing this allows the panel’s 
programming configuration to be properly transferred to 
the touch screen. 

x

 

Program (learn) the touch screen into the panel as a 
sensor Using group types 00, 01, 04, 05, 06, or 07. 

x

 

The touch screen will work best if mounted greater than 
3 ft. (approximately 1 m) from the Simon panel.  

x

 

Avoid mounting the touch screen directly behind the 
Simon XT, XTi, XTi-5 or XTi-5 V2 panel on the opposite 
side of the wall.  

x

 

Always do a sensor test before attaching the touch screen 
to the wall. 

Summary of Contents for 60-924-RF-TS5-2

Page 1: ...el x Customize color and fonts matching the interactive service on the mobile phone Xti 5 Panel Version 2 only Safety Information IMPORTANT SAFETY INFORMATION READ ENCLOSED WARNINGS AND SAFETY INFORMATION WARNING CHOKING HAZARD The product accessory bag contains items that could be choking hazards Please keep away from small children WARNING Disconnect panel power before servicing CAUTION Use stat...

Page 2: ...ch screen mounting base is connected to the corresponding positive and negative lead on the power supply Do not use different or longer run cable than the supplied wiring as the DC power supply may not support it and intermittent power failures in the touch screen may occur due Figure 4 Power connector 5 Reattach the touchscreen to the mounting base plate Angle the top of the touch screen into the...

Page 3: ...ouch screen should indicate it is waiting for enrollment 6 On the panel you can now program the group number 00 01 04 05 06 or 07 by pressing EDIT next to Sensor Group 7 On the panel select a name for the touch screen by pressing EDIT next to Sensor Name You can select something simple such as Touch Pad or use additional descriptors such as Bedroom Touch Pad The touch screen will indicate enrollme...

Page 4: ...you cannot get the touch screen to trip test a known good touch screen at the same location If the replacement touch screen functions contact UTC Fire Security for repair or replacement of the faulty touch screen Mounting 1 With touch screen operation verified and tested at the permanent location mount the touchscreen either on the wall or on a surface with the supplied desktop stand Surface deskt...

Page 5: ...ed to be checked by a qualified technical at least every 3 years Setting the clock You can set the touch screen clock by setting the clock on the Simon XT XTi XTi 5 or XTi 5 V2 panels Battery Pack Replacement We recommend that you replace the backup battery pack every 3 5 years Only the part 60 924 BAT4SIMONTS5 can be used as a battery pack replacement 1 Remove the touch screen from the mounting p...

Page 6: ...lled by the following sensors All sensors learned into Group 43 Sensors that are not named window or door Sensors not learned into the Motion groups Sensors that are named keyfob or keychain Specifications Compatibility Simon XT version 1 3 and later Simon XTi Simon XTi 5 Enhanced Compatibility XTi 5 Version 2 i e 80 zone encryption GUI Power Input 100 120 VAC 250 mA Output 6 VDC 1000 mA Backup ba...

Page 7: ...ser un mauvais fonctionnement du dispositif Conforms to UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units ULC C1023 Preliminary Standard for Household Burglar Alarm ULC S545 Standard For Residential Fire Warning System Control Units Warnings and Disclaimers THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS UTC FIRE SECURITY CA...