background image

 P/N 466-5438 • REV A • ISS 16OCT18 

 

5 / 7 

14.  Reconnect the ends of the wire to the power terminals as 

identified in Figure 4, taking particular care to ensure the 
marked/dashed wire attaches to the Positive lead and the 
unmarked wire attaches to the Negative lead.  

15.  Feed any extra wire back into wall. Wires should not 

protrude outside of the wire drop opening. 

16.  Reattach the touch screen to the mounting base. Angle 

the top of the touch screen into the tab hooks on the top of 
the mounting base and swing the bottom of the touch 
screen into the lower part of the mounting base until you 
hear an audible click.  

17.  Reconnect the spaded ends of the power supply wire to 

the terminal to the terminals on the power supply.  

Note: 

The dashed line/writing side of the wire indicates 
positive. Ensure consistency by wiring the + to + and – to 
– as polarity must be observed or touchscreen will not 
function.

Operation

Refer to 

Simon 5” TouchScreen User Guide

 for basic touch 

screen operation information. Refer to the panel 
documentation for complete Simon XT, XTi, XTi-5 and XTi-5 
V2 programming and operation information. 

Note: 

Test system at least once per week.

Note: 

Each control unit shall indicate that the system is intended to 
be checked by a qualified technical at least every 3 years. 

Setting the clock 

You can set the touch screen clock by setting the clock on the 
Simon XT, XTi, XTi-5, or XTi-5 V2 panels. 

Battery Pack Replacement 

We recommend that you replace the backup battery pack 
every 3-5 years. Only the part 60-924-BAT4SIMONTS5 can be 
used as a battery pack replacement. 

1.  Remove the touch screen from the mounting plate by 

depressing the button on the bottom of the touch screen. 

2.  Remove the five screws from the back cover of the touch 

screen and separate the back cover off the front cover. 

3.  Disconnect the battery from the battery connector and 

remove the battery as showing in Figure 6. Replace the 
battery pack.  

Avoid touching the touch screen face while you are replacing 
the batteries. 

Figure 6:  Battery 

Note: 

If AC power is lost and battery pack is not present or 
depleted, the touch screen will not power up until AC power 
is restored (even if a new battery pack is installed). 

Reset Button 

The Reset button is located on the bottom right side of the 
touch screen mounting plate (see Figure 7). To power cycle 
the touch screen, use a toothpick to depress the recessed 
Reset button. Note the reset has no impact on the Simon panel 
or the overall state of the alarm system. The button simply 
resets the only the touch screen to the same state 

Note: 

Do not press the Reset button while in programming mode. 

Figure 7:  Reset 

Summary of Contents for 60-924-RF-TS5-2

Page 1: ...el x Customize color and fonts matching the interactive service on the mobile phone Xti 5 Panel Version 2 only Safety Information IMPORTANT SAFETY INFORMATION READ ENCLOSED WARNINGS AND SAFETY INFORMATION WARNING CHOKING HAZARD The product accessory bag contains items that could be choking hazards Please keep away from small children WARNING Disconnect panel power before servicing CAUTION Use stat...

Page 2: ...ch screen mounting base is connected to the corresponding positive and negative lead on the power supply Do not use different or longer run cable than the supplied wiring as the DC power supply may not support it and intermittent power failures in the touch screen may occur due Figure 4 Power connector 5 Reattach the touchscreen to the mounting base plate Angle the top of the touch screen into the...

Page 3: ...ouch screen should indicate it is waiting for enrollment 6 On the panel you can now program the group number 00 01 04 05 06 or 07 by pressing EDIT next to Sensor Group 7 On the panel select a name for the touch screen by pressing EDIT next to Sensor Name You can select something simple such as Touch Pad or use additional descriptors such as Bedroom Touch Pad The touch screen will indicate enrollme...

Page 4: ...you cannot get the touch screen to trip test a known good touch screen at the same location If the replacement touch screen functions contact UTC Fire Security for repair or replacement of the faulty touch screen Mounting 1 With touch screen operation verified and tested at the permanent location mount the touchscreen either on the wall or on a surface with the supplied desktop stand Surface deskt...

Page 5: ...ed to be checked by a qualified technical at least every 3 years Setting the clock You can set the touch screen clock by setting the clock on the Simon XT XTi XTi 5 or XTi 5 V2 panels Battery Pack Replacement We recommend that you replace the backup battery pack every 3 5 years Only the part 60 924 BAT4SIMONTS5 can be used as a battery pack replacement 1 Remove the touch screen from the mounting p...

Page 6: ...lled by the following sensors All sensors learned into Group 43 Sensors that are not named window or door Sensors not learned into the Motion groups Sensors that are named keyfob or keychain Specifications Compatibility Simon XT version 1 3 and later Simon XTi Simon XTi 5 Enhanced Compatibility XTi 5 Version 2 i e 80 zone encryption GUI Power Input 100 120 VAC 250 mA Output 6 VDC 1000 mA Backup ba...

Page 7: ...ser un mauvais fonctionnement du dispositif Conforms to UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units ULC C1023 Preliminary Standard for Household Burglar Alarm ULC S545 Standard For Residential Fire Warning System Control Units Warnings and Disclaimers THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS UTC FIRE SECURITY CA...

Reviews: