Appendix 4 Ladder Transfer Function
App4-5
How to check the COM port setting for the PLC
To see which port must be set for [COM port] in the [Ladder Transfer Setting] dialog, go to the following dialog provided in the
PLC ladder software.
•
MITSUBISHI ELECTRIC GX Developer
•
Fuji Electric SX-Programmer Expert (D300win)
Notes
•
The ladder transfer function can be used with PLC1. It cannot be used with PLC2.
•
On-line editing between the editor and the S8 series is not possible. If attempted, communications between the PLC
programming software and the PLC will not be performed correctly.
•
Communicating statuses with the PLC programming software and the PLC during communications between the editor
and the S8 series
•
Baud rate setting
The [Baud Rate] setting in the [Communication Setting] tab window applies to the baud rate between the S8 series and
the PLC. However, if communication with the PLC programming software (monitoring, etc.) starts by means of the ladder
transfer function, the baud rate set on the software takes effect. The baud rate stays enabled until the S8 series is turned
off and on again. Keeping this in mind, set the PLC programming software baud rate and the [Baud Rate] setting in the
[Communication Setting] tab window to the same value.
•
With [Use Ladder Tool] checked, it is prohibited to register the devices to be monitored for S8-PLC communication even
though the PLC programming software is not started. The screen display speed will decrease somewhat accordingly.
•
When the ladder program is transferred in the RUN mode of the S8 series, communications are synchronized; therefore,
the performance of both the S8 series and the PLC programming software decreases.
•
Ladder transfer is possible only in the RUN mode. When transferring the screen data, be sure to display the Main Menu
screen on the S8 series.
•
When [
COM port] is checked, every serial communication that uses the COM port you selected will be converted to
communication via USB. Therefore, be sure that the COM port selected under [COM port] is not already used for other
serial communications. Except when ladder transfer via USB is used, uncheck the box for [
COM port].
Editor
PLC Programming Software
Writing to S8
Communications disconnected (normal communications on completion of writing)
Reading from S8
Normal communications
Comparing with S8
Normal communications
Summary of Contents for Monitouch S8 series
Page 1: ...Connection Manual...
Page 3: ......
Page 5: ......
Page 17: ......
Page 19: ......
Page 43: ...1 24 1 Overview...
Page 44: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 45: ......
Page 56: ...3 1 PLC Connection 3 Automation Direct...
Page 57: ......
Page 66: ...4 EATON Cutler Hammer 4 1 PLC Connection...
Page 67: ......
Page 71: ...4 4 4 EATON Cutler Hammer Please use this page freely...
Page 72: ...5 FANUC 5 1 PLC Connection...
Page 73: ......
Page 78: ...6 FATEK AUTOMATION 6 1 PLC Connection...
Page 79: ......
Page 84: ...7 Fuji Electric 7 1 PLC Connection 7 2 Temperature Controller Servo Inverter Connection...
Page 85: ......
Page 158: ...8 IAI 8 1 Temperature Controller Servo Inverter Connection...
Page 159: ......
Page 173: ...8 14 8 IAI Please use this page freely...
Page 174: ...9 KEYENCE 9 1 PLC Connection...
Page 175: ......
Page 186: ...10 LS 10 1 PLC Connection...
Page 187: ......
Page 197: ......
Page 223: ...11 26 11 MITSUBISHI ELECTRIC Please use this page freely...
Page 224: ...12 OMRON 12 1 PLC Connection 12 2 Temperature Controller Servo Inverter Connection...
Page 225: ......
Page 244: ...13 Panasonic Electric Works 13 1 PLC Connection...
Page 245: ......
Page 253: ...13 8 13 Panasonic Electric Works Please use this page freely...
Page 254: ...14 RKC 14 1 Temperature Controller Servo Inverter Connection...
Page 255: ......
Page 264: ...15 SAIA 15 1 PLC Connection...
Page 265: ......
Page 269: ...15 4 15 SAIA Please use this page freely...
Page 270: ...16 1 PLC Connection 16 Siemens...
Page 271: ......
Page 276: ...17 1 Temperature Controller Servo Inverter Connection 17 Yamatake...
Page 277: ......
Page 285: ...17 8 17 Yamatake Please use this page freely...
Page 286: ...18 Yaskawa Electric 18 1 PLC Connection...
Page 287: ......
Page 295: ...18 8 18 Yaskawa Electric Please use this page freely...
Page 296: ...19 1 PLC Connection 19 2 Temperature Controller Servo Inverter Connection 19 Yokogawa Electric...
Page 297: ......
Page 307: ...19 10 19 Yokogawa Electric Please use this page freely...
Page 308: ...20 1 PLC Connection 20 MODBUS...
Page 309: ......
Page 314: ...21 1 Barcode Reader Connection 21 Barcode Reader...
Page 315: ......
Page 320: ...22 1 V Link 22 2 Modbus RTU Slave Communication 22 Slave Communication Function...
Page 321: ......
Page 333: ...22 12 22 Slave Communication Function Please use this page freely...
Page 335: ......
Page 367: ...23 32 23 Universal Serial Communication Please use this page freely...
Page 369: ......
Page 403: ...App4 6 Please use this page freely...