23-6
23. Universal Serial Communication
Universal Serial
*1
Interrupt settings can be changed from the host using the [WI] command during communication.
For details on interruption, see “23.4.4 Interrupt (ENQ)”.
Text Process
When using text process, choose either [LSB
→
MSB] or [MSB
→
LSB] in order to make arrangements for
the order of the first and the second bytes in one word.
[LSB
→
MSB]
MSB
LSB
15
0
2nd byte
1st byte
[MSB
→
LSB]
MSB
LSB
15
0
1st byte
2nd byte
Read Clear Top Address
*2
Set the top address number of the read clear area.
The read clear area is the starting area from which the S8 series clears data that was previously read.
Due to the fact that it is cleared to “0”, once this area is read, the data remains at “0” even if you attempt
to read again when a read response error occurs.
Read Clear Word Counts
*2
Set the number of words that will be used for clearing the read area.
Read Clear Saving
*2
Set the top address for the read clear backup area. The area size will be the same as the previously
described read clear area.
The number of words written in the read clear backup area are the same as the number specified for the
read clear area.
Switch ON Interrupt
*1
Select whether or not to enable or disable an interrupt when the switch changes from OFF to ON.
Switch OFF Interrupt
*1
Select whether or not to enable or disable an interrupt when the switch changes from ON to OFF.
Keypad Interrupt
*1
Select whether or not to enable or disable an interrupt when the switch on the keypad or the ENT switch
on the keyboard is pressed and it changes from OFF to ON.
Screen Interrupt
*1
Select whether or not to enable or disable an interrupt when the screen change switch is pressed.
Flow Control
This option is valid only for 1 : 1 communication via RS-232C using COM2.
Check this box when disabling an interrupt from the S8 series (e.g. when the host cannot receive
interrupt data).
When this box is checked, the action shown below takes place.
• Interrupt enabled when CS (pin 8) on the S8 series side is ON
• Interrupt disabled when CS (pin 8) on the S8 series side is OFF
When CS is ON, interruption information stored by then is output in succession. (Interruption
information for 3 times can be stored at the most.)
Do not turn output OFF
This option is valid only for 1 : 1 communication via RS-422 using four-wire.
Normally, S8 series uses the same cables to send or receive data. For this reason, send output
remains OFF (High impedance) except for sending signals from S8 series.
However, depending on the host specifications, send output OFF operation from the S8 series is not
required. In this case, check [
Do not turn output OFF].
2-Wire System
This option is valid only for 1 : 1 communication with RS-422 using two-wire.
When this box is checked, interrupt is disabled.
Summary of Contents for Monitouch S8 series
Page 1: ...Connection Manual...
Page 3: ......
Page 5: ......
Page 17: ......
Page 19: ......
Page 43: ...1 24 1 Overview...
Page 44: ...2 1 PLC Connection 2 ALLEN BRADLEY...
Page 45: ......
Page 56: ...3 1 PLC Connection 3 Automation Direct...
Page 57: ......
Page 66: ...4 EATON Cutler Hammer 4 1 PLC Connection...
Page 67: ......
Page 71: ...4 4 4 EATON Cutler Hammer Please use this page freely...
Page 72: ...5 FANUC 5 1 PLC Connection...
Page 73: ......
Page 78: ...6 FATEK AUTOMATION 6 1 PLC Connection...
Page 79: ......
Page 84: ...7 Fuji Electric 7 1 PLC Connection 7 2 Temperature Controller Servo Inverter Connection...
Page 85: ......
Page 158: ...8 IAI 8 1 Temperature Controller Servo Inverter Connection...
Page 159: ......
Page 173: ...8 14 8 IAI Please use this page freely...
Page 174: ...9 KEYENCE 9 1 PLC Connection...
Page 175: ......
Page 186: ...10 LS 10 1 PLC Connection...
Page 187: ......
Page 197: ......
Page 223: ...11 26 11 MITSUBISHI ELECTRIC Please use this page freely...
Page 224: ...12 OMRON 12 1 PLC Connection 12 2 Temperature Controller Servo Inverter Connection...
Page 225: ......
Page 244: ...13 Panasonic Electric Works 13 1 PLC Connection...
Page 245: ......
Page 253: ...13 8 13 Panasonic Electric Works Please use this page freely...
Page 254: ...14 RKC 14 1 Temperature Controller Servo Inverter Connection...
Page 255: ......
Page 264: ...15 SAIA 15 1 PLC Connection...
Page 265: ......
Page 269: ...15 4 15 SAIA Please use this page freely...
Page 270: ...16 1 PLC Connection 16 Siemens...
Page 271: ......
Page 276: ...17 1 Temperature Controller Servo Inverter Connection 17 Yamatake...
Page 277: ......
Page 285: ...17 8 17 Yamatake Please use this page freely...
Page 286: ...18 Yaskawa Electric 18 1 PLC Connection...
Page 287: ......
Page 295: ...18 8 18 Yaskawa Electric Please use this page freely...
Page 296: ...19 1 PLC Connection 19 2 Temperature Controller Servo Inverter Connection 19 Yokogawa Electric...
Page 297: ......
Page 307: ...19 10 19 Yokogawa Electric Please use this page freely...
Page 308: ...20 1 PLC Connection 20 MODBUS...
Page 309: ......
Page 314: ...21 1 Barcode Reader Connection 21 Barcode Reader...
Page 315: ......
Page 320: ...22 1 V Link 22 2 Modbus RTU Slave Communication 22 Slave Communication Function...
Page 321: ......
Page 333: ...22 12 22 Slave Communication Function Please use this page freely...
Page 335: ......
Page 367: ...23 32 23 Universal Serial Communication Please use this page freely...
Page 369: ......
Page 403: ...App4 6 Please use this page freely...