Subject: 

NEW Concord 5” Touchscreen Version 2 with the firmware version above 2.1B is equipped with a 

new functionality allowing patching the panel from version 4.82 to version 4.82X. 4.82X is the 

functional equivalent of 4.83. Patch functionality works with: Concord 4 Residential and Concord 4 

Commercial firmware version 4.82. 

Info: 
Patching Procedure 

1. 

Connect the Concord 5’’ Touchscreen Version 2 with the firmware version above 2.1B to 

the Concord 4 panel Residential/ Commercial. 

 

2. 

Turn on the Concord 4 panel by turning on AC power and connecting the backup battery. 

 

3. 

Allow the Concord 4 panel to scan for bus devices. 

 

4. 

Wait until the Touchscreen Version 2 displays the message “ATTENTION! Incompatible 

panel detected! Press here to perform panel patching.”(The message will only appear in 

Concord 4 panel version 4.82) 

 

5. 

Press the message displayed on the Touchscreen Version 2.  

 

 

 

 