Release Note: Interlogix, NEW Concord 5” Touchscreen with Firmware Patching Mechanism
1
©10/10/2019 United Technologies Corporation. Interlogix is part of UTC Fires & Security, a unit of United Technologies Corporation. All rights reserved.
TECHNICAL NOTE
NEW Concord 5" Touchscreen (60-924-3-C4TS5-2)
with Firmware Patching Mechanism
1.0
Release Date: 10/21/2019
Subject:
NEW Concord 5” Touchscreen Version 2 with the firmware version above 2.1B is equipped with a
new functionality allowing patching the panel from version 4.82 to version 4.82X. 4.82X is the
functional equivalent of 4.83. Patch functionality works with: Concord 4 Residential and Concord 4
Commercial firmware version 4.82.
Info:
Patching Procedure
1.
Connect the Concord 5’’ Touchscreen Version 2 with the firmware version above 2.1B to
the Concord 4 panel Residential/ Commercial.
2.
Turn on the Concord 4 panel by turning on AC power and connecting the backup battery.
3.
Allow the Concord 4 panel to scan for bus devices.
4.
Wait until the Touchscreen Version 2 displays the message “ATTENTION! Incompatible
panel detected! Press here to perform panel patching.”(The message will only appear in
Concord 4 panel version 4.82)
5.
Press the message displayed on the Touchscreen Version 2.