30
4)
VSF/TG linkage system (maximum inputs and outputs)
Usually, the VSF/TG linkage function is used for the system in which there are more
inputs than outputs. If the numbers of inputs and outputs are the same, connecting the
TG-1616 before or after the VSF does not make any difference to the number of
TG-1616, but in a system like that shown in the figure above, the number of outputs can
be gradually expanded from 16 and support up to 128 outputs is possible.
The maximum total cable length from
the VSF-128128 to the final stage of
TG-1616 is 100 m.
Cameras
1 to 128
Routing switcher
VSF-128128
1
128
RU-3000
SERIAL I/F A
SERIAL I/F B
REMOTE1
REMOTE2
TG-1616
ID
:
0
Terminal: OFF
SERIAL I/F
TG-1616
ID
:
1
Terminal: OFF
SERIAL I/F
TG-1616
ID
:
2
Terminal: OFF
SERIAL I/F
TG-1616
ID
:
3
Terminal: OFF
SERIAL I/F
TG-1616
ID
:
4
Terminal: OFF
SERIAL I/F
TG-1616
ID
:
5
Terminal: OFF
SERIAL I/F
TG-1616
ID
:
6
Terminal: OFF
SERIAL I/F
TG-1616
ID
:
7
Terminal: ON
Monitor 1
Monitor 16
Monitor 17
Monitor 32
Monitor 33
Monitor 48
Monitor 49
Monitor 64
Monitor 65
Monitor 80
Monitor 81
Monitor 96
Monitor 97
Monitor
112
Monitor
113
Monitor
128
1
16
17
32
33
48
49
64
65
80
81
96
97
112
113
128
SERIAL I/F
Term
1
16
17
32
33
48
49
64
65
80
81
96
97
112
113
128
Summary of Contents for VSF-128128
Page 2: ......
Page 8: ......
Page 12: ......
Page 103: ...91 12 2 External Dimensions All dimensions in mm...
Page 104: ......