71
9-9-3. Logical Input Channel Assignment
An example of the command to set a logical switching source channel for a physically
connected input channel is shown in the box below.
Assign logical source channel number
in numeric order from physical input channel 1 of the routing switcher.
Contents
Item
Parameter
Description
Src
0001 – Max. Src
Logical source channel to be assigned
E.g.
To assign physical sources as logical sources on switching level 1, use a command like
below.
Physical channel
Logical channel
1
→
8
2
→
7
3
→
6
4
→
5
5
→
4
6
→
3
7
→
2
8
→
1
9
→
9
10
→
10
• •
• •
Max. Src
→
Max.
Src
M S 1 0
0
0
8
0
0
0 7
0 0 0 6
0
0
0
5
0
0 0 4
0 0 0 3
0
0
0
2
0
0 0 1
0 0 0 9
0
0
1
0
* * *
*
CR LF
(Command)
O K CR LF
(Response)
Command MS 1 Src (4) x Max. Src CR+LF
Response
OK CR+LF
(
Ends normally
)
ER CR+LF
(
Ends abnormally
)
Src
Src
Src
Src
Src
Src
Src
Src
Src
Src
Max.Src
Summary of Contents for VSF-128128