34
8-3. Communication Parameters
When controlling units via personal computer command, set communication parameters as
shown below.
IMPORTANT
Control protocol is factory set to RS-232C. See section 4-3.
for details on
internal protocol setting.
Communication Parameters
Baud rate
9,600 (bps), 19,200 (bps), 38,400 (bps)
(Factory setting is 9,600(bps ).
For details on internal protocol setting, see section
6-2-2. "RS-232C/RS-422 Baud Rate Setting
Data bits
8bit
Parity
None
Stop bits
1bit
X parameters (Flow control) None
Synchronization
Start-stop (asynchronous)
8-4. Protocol
All control and response commands are in ASCII code.
IMPORTANT
Do not send a command before receiving a response message from VSF-600 for the
previous command. If you do not receive a response from a router for more than 1
second, re-send the command.
t
(
Time
)
Control command
Response command
Control computer
(PC)
VSF-600