55
9-3-3. Stopping Sequence Switching
This designates the sequence registration number and stops the sequence switching
operation.
Contents
Item
Parameter
Description
SQ Num
01 – 16
Sequence registration number
9-3-4. Confirming Sequence Switching
An example of the command to confirm the registered sequence switching information is
shown in the box below.
Contents
Item
Parameter
Description
SQ Num
01 – 16
Sequence registration number
Dest
001 – Max. Dest
Target destination channel
Time
001 – 255
0.5-second units up to maximum of 127.5
seconds
Src
0001 – Max. Src
Automatically selected source channels
(Channels can be duplicated)
Command AQE SQ Num (2) CR+ LF
Response OK
CR+LF
(
Ends normally
)
ER CR+LF
(
Ends abnormally
)
Command AQR SQ Num (2) CR+ LF
Response AQA Dest (3) Time(3) [ Src (4)
x Max. 128 Src
] CR+LF
(
Ends normally
)
ER CR+LF
(
Ends abnormally
)