28
7-4. VSF/TG Linkage
Normally, when a title is inserted to a camera video, title generators (TG-1616) corresponding to
the number of cameras are required. However, the VSF/TG linkage function can be used to
reduce the number of TG-1616 units.
The TG-1616 and VSF-600 can be connected with a dedicated serial bus to enable title page
switching by the TG-1616 in coordination with switching of crosspoints by the routing switcher.
The three block diagrams and a table below are showing differences when the VSF/TG linkage
function is used and not used. (Select the VSF/TG linkage function based on the system.)
1) System without VSF/TG linkage (96 cameras x 32 monitors)
2) VSF/TG linkage system (96 cameras x 32 monitors)
3) Comparison table of 1) and 2)
4) VSF/TG linkage system (maximum inputs and outputs)
1) System without VSF/TG linkage (96 cameras
×
32 monitors, when using VSF-9632)
64
64
Cameras
1 to 96
Routing switcher
VSF-9632
1
Monitor
1
Monitor
16
16
TG-1616
TG-1616
TG-1616
TG-1616
1
16
17
32
33
48
49
1
16
17
32
33
48
49
The TG-1616 is placed
before the routing switcher.
One TG-1616 is required
for 16 camera inputs
SERIAL I/F
RU-3000 remote
control unit
REMOTE
Terminator
Terminator
TG-1616
65
80
65
80
TG-1616
81
96
81
96
REMOTE