89
12. Specifications & Dimensions
12-1. Unit Specifications
Video Inputs
1.0 Vp-p, 75
Ω
, BNC
Video Outputs
1.0 Vp-p within
±
1.0 dB of routed input, 75
Ω
, BNC
Output DC
Within
±
50 mV of routed input (DC coupled output, offset from input)
Frequency
response
100 kHz - 5 MHz, within
±
1.0 dB;
Roll off response above 5MHz (When 100 kHz reference)
DG / DP
Within 1 % / 1º
Crosstalk
47dB/50 dB or more (at 4.43 MHz) (All / adjacent)
S/N ratio
60 dBp-p/rms or more
Ref Input
B.B. (black burst), 0.429 Vp-p (NTSC), or composite sync, 0.286 Vp-p
(NTSC), 75
Ω
or loopthru (auto select), 1 ea., BNC
Ref Output
Loopthru output from Ref Input, 1 ea., BNC
Interfaces
RS-232C / RS-422 / SERIAL I/F(through) interface, switchable with the
internal jumper setting.
RS-232C/422 9-pin D-sub (male) (inch type lock screws)
SERIAL I/F
9-pin D-sub (female) (inch type lock screws) 2 ports
For connection to RU-3000 remote control units and TG-1616 title
generator units
Alarm out
ML-400NV3P
(
SATO PARTS product
)
For detecting error or defect in power unit, cooling fan or CPU card,
and outputting no-voltage make contact alarm signal
Maximum currency 200mA
Power 100VAC-240VAC
±10%,
50/60Hz
Consumption
250VA (230W) Max.
Temperature
0 °C - 40 °C
Humidity
30 % - 90 % (no condensation)
Battery
Approx. 5 years usable life
Clock Accuracy
±90 seconds per month (25 degrees C)
Dimensions
424(W) x 265(H) x 375(D)mm
Weight
Approx. 18 kg