Summary of Contents for OSP Series

Page 1: ...R S OSP Open Switch and Control Platform Getting Started Getting Started Version 03 1178711702 A2...

Page 2: ...download at https www rohde schwarz com product osp Manuals The software contained in this product uses several valuable open source software packages For infor mation see the Open Source Acknowledgme...

Page 3: ...7 Release Notes Open Source Acknowledgment 12 3 8 Application Notes Cards White Papers etc 12 4 Preparing for Use 13 4 1 Unpacking and Checking the Switch Unit 13 4 2 Accessory List 14 4 3 Placing or...

Page 4: ...5 2 3 Rear Panel of the R S OSP320 26 5 2 4 Rear Panel of the R S OSP B200S2 Satellite Unit 27 6 Trying Out the Switch Unit 29 6 1 Manual and Remote Modes of Operation 29 6 1 1 Direct Manual Operatio...

Page 5: ...nformation is provided as follows In the Basic Safety Instructions safety issues are grouped according to sub jects For example one subject is electrical safety The Basic Safety Instruc tions are deli...

Page 6: ...rmation on appropriate operating conditions provided in the basic safety instructions and the instrument s data sheet Risk of electrostatic discharge ESD Electrostatic discharge ESD can damage the ele...

Page 7: ...e specified in the data sheet Risk of instrument damage due to insufficient airflow in a rack If you mount several instruments in a rack you need an efficient ventilation concept to ensure that the in...

Page 8: ...often considered to be equivalent with the term failsafe relay but this interpretation is misleading Failsafe means that the relay is designed to cause minimum or no harm if there is a failure To real...

Page 9: ...n of switch units from Rohde Schwarz replacing the R S OSP120 130 150 Outstanding key features are 5 to 10 module slots and up to 16 module buses provide maximum flexibility Fast setup of test and mea...

Page 10: ...s by their connectors M01 to M16 in a switch unit In setting commands the firmware alternatively accepts addressing the modules by A11 A12 or A13 according to the 3 module connec tor buses in a legacy...

Page 11: ...on is delivered with the switch unit 3 2 User Manual Contains the description of all switch unit modes and functions It also provides an introduction to remote control a complete description of the re...

Page 12: ...cifications of the R S OSP It also lists the firmware applications and their order numbers and optional accessories The brochure provides an overview of the instrument and deals with the specific char...

Page 13: ...e Installed Modules 19 4 7 Configuring the Initial Instrument Settings 19 4 1 Unpacking and Checking the Switch Unit Check the equipment for completeness using the delivery note and the accessory list...

Page 14: ...ecure the instrument to prevent any movement and other mechanical effects during transportation 4 2 Accessory List The R S OSP base unit comes with the following accessories Printed Getting Started ma...

Page 15: ...the instruments on top Observe the following instructions when stacking instruments Never stack more than three instruments If you need to stack more than three instruments install them in a rack The...

Page 16: ...not exceed 500 N Fmax Rack mounting You can install the R S OSP in a 19 rack using one of the following optional rack adapter kits For 2 HU R S OSP220 and R S OSP230 use R S ZZA 211 order no 1096 326...

Page 17: ...g the fuses refer to the maintenance chapter in the User Manual 4 5 Switching the Instrument On and Off Switching on Set the AC power switch on the rear panel to position I The instrument is supplied...

Page 18: ...SP B300M needs no burn in protection Thus it has no timeout Risk of losing settings While the R S OSP is in operating mode if you switch it off using the rear panel switch or by disconnecting the powe...

Page 19: ...ts on page 31 Figure 4 1 The module operation dialog here with a master switch unit and 5 modules The information in this dialog is updated during the booting process when the R S OSP automatically de...

Page 20: ...e Unit 22 5 1 5 Touchscreen 23 5 1 1 Front Panel of the R S OSP220 The front panel of the R S OSP220 features 3 module slots a monochrome non touch mini display a power switch and various connectors T...

Page 21: ...with a blind plate FS02 Front slot 02 here with a 1 slot switch module Disp Integrated touchscreen display F Int Front interfaces see Figure 6 4 5 1 3 Front Panel of the R S OSP320 The R S OSP320 is h...

Page 22: ...onal see p 23 It can only be factory mounted in the R S OSP320 with 3 height units 3HU in position FS04 FS05 You cannot insert any modules into the R S OSP320 that are designed as 2 slot or 3 slot mod...

Page 23: ...rol module R S OSP B200R For example you can use the satellite unit inside a shielded chamber for EMC tests that do not tolerate electrical wiring In this scenario use the satellite with local battery...

Page 24: ...ap on the screen and vice versa Using the touchscreen you can perform all tasks by the tap of your finger For the remainder of this manual all interactions are described for a click action These descr...

Page 25: ...anel of the R S OSP220 features 3 module slots an on off switch fuses power supply connector LAN and USB connectors and a micro SD card slot You can insert 1 slot 2 slot or 3 slot modules into the 3 r...

Page 26: ...r supply connector LAN and USB connectors and a micro SD card slot Figure 5 9 Rear view of the R S OSP320 3HU R Int Rear interfaces see Figure 6 4 with an additional D Sub 9 trigger connector RS01 Rea...

Page 27: ...For a comprehensive description of this unit also refer to the R S OSP B200R B200S2 Satellite System User Manual available for download at www rohde schwarz com manual osp The rear panel of the R S O...

Page 28: ...lusively to the remote control interface module R S OSP B200R in your base switch unit Connecting it to any other device or module can harm your equipment The wired link cable supplies power from the...

Page 29: ...des of Operation You can operate the switch unit by any of the following modes Direct Manual Operation 29 Manual Remote Operation 30 Remote Operation by SCPI Commands 30 6 1 1 Direct Manual Operation...

Page 30: ...to the User Manual for more information also regarding the combination of several switch units in a master slave setup Note that the legacy software R S OSP Panel is not compatible with the switch un...

Page 31: ...subnet mask in the last 2 lines You cannot operate the switch units R S OSP220 and the R S OSP320 with out display module R S OSP B300M by their micro displays To operate these switch units without t...

Page 32: ...ect an external monitor to the HDMI connector 5 use a monitor that is compatible with this port s DVI signal which has the touchscreen s resolution of 800 x 480 pixels Incompatible monitors cannot dis...

Page 33: ...s of the graphical user interface GUI 1 Main menu 2 Module operation 3 Path switching 4 Device configuration 5 Context menu always used together with one of the menu buttons above 6 Status line with v...

Page 34: ...any of the menu items shown above and listed as 1 to 4 in Figure 6 6 Hence this button is always used together with one of the other buttons For more information refer to the User Manual 6 4 Elements...

Page 35: ...ne switch module right If you see the interaction dialog of one switch module click to see the list of installed modules Then click the name of any module to see its interaction dialog 6 5 1 Switching...

Page 36: ...ted Green circle Items selected indicator The icon is highlighted if at least one relay or output channel in any module is selected Orange frames Selected relays and output channels are highlighted in...

Page 37: ...9 Full screen representation of several modules in a browser window On the contrary to reproduce the original size of the touchscreen display set your browser window to 800 480 pixels Optionally hit F...