4-9
Configuring Surveyor
Module Settings (Properties)
4
For THGm modules, the default is no packet slicing (full packet length). For
THGm, the slicing size must be 64 bytes or greater and packet slicing of 128 bytes
is not supported for 1Gbps Ethernet.
For Portable Surveyor 10/100 Ethernet Analyzer Cards, and NDIS cards, the default
setting is no packet slicing for capture, 128-byte packet slice for monitor. For NDIS
modules, you cannot have both monitor and capture set to full packet size.
Stop-and-Save Capture Buffer
Only local devices support a stop-and-save-to-disk function for the capture buffer.
Check the
Enable Full Buffer Auto Save
box to enable the save-to-disk feature.
When using the save-to-disk feature, capture is stopped when the buffer is full and
the contents are written to disk. Capture is restarted as soon as the data is written to
the file. When the capture buffer fills again, the new contents are appended to the
file. If you start a new capture, the file is overwritten. If capture is stopped before
the capture buffer contents are full, the buffer contents are not automatically written
to disk; you must manually save the capture buffer to disk.
Modes
Select the
Modes
tab from the
Configuration
→
Module
→
Settings...
to set the
modes for a module.
Expert Analysis Mode
Expert Views and Alarms can be disabled. When disabled, no Expert Views or
Alarms will display in Surveyor software.
Uncheck the
Enable Expert Analysis Mode
box to disable Expert Views and Alarms.
The default is to enable Expert Analysis. If you do not have the Expert plug-in, you
cannot enable Expert Analysis Mode.
Non-Well-Known-Ports Mode
Non-well-known port (non-WKP) numbers in tables can be enabled or disabled for
each module when monitoring with local devices. When disabled, most port num-
bers above 1023 display as
TCP Other
or
UDP Other
with no port number pro-
vided.
It is recommended that you leave this feature disabled unless you are looking for
specific port numbers greater than 1023, since non-WKP numbers can quickly fill
Application Layer Tables. Surveyor always displays the port number if the number
is less than or equal to 1023. Surveyor also displays some ports above 1023 since
applications associated with them are widely accepted.
Check the
Monitor TCP/UDP non-well-known-ports individually
box to enable the
display of all non-WKP numbers. The default is to not display these port numbers.
With the option enabled all TCP packets with non-WKP numbers (TCP or UDP)
Summary of Contents for Surveyor
Page 1: ...Surveyor User s Guide ...
Page 30: ...1 10 Surveyor User s Guide ...
Page 40: ...2 10 Surveyor User s Guide ...
Page 88: ...4 28 Surveyor User s Guide ...
Page 184: ...8 16 Surveyor User s Guide ...
Page 204: ...9 20 Surveyor User s Guide ...
Page 207: ...10 3 Expert Features Getting Started with Expert View10 Figure 10 1 Expert Overview Example ...
Page 211: ...10 7 Expert Features Expert Layers 10 Figure 10 3 Expert Application Layer Example ...
Page 368: ...11 34 Surveyor User s Guide ...
Page 390: ...13 12 Surveyor User s Guide ...
Page 416: ...C 4 Surveyor User s Guide ...
Page 426: ...D 10 Surveyor User s Guide ...
Page 454: ...Index 14 Surveyor User s Guide ...