10-104
Surveyor
User’s Guide
CRC Frame counter
Counter
The CRC Frame counter increments when a frame has a CRC error and is greater
than 63 bytes in length. A count of all CRC Frames is included in the Bad Frames
counter. The CRC Frame counter is used for Expert Alarms.
Expert Symptom
CRC Frame events are automatically logged as expert symptoms. The
Symptom
Summary
field contains the following information:
CRC error with more than 63 bytes
Diagnostic Details
__________________________________________________________________
Problem Description:
A packet with more than 63 bytes of data and a CRC error has been received.
__________________________________________________________________
Probable Cause(s):
1. The network is overloaded, resulting in too many collisions.
2. A faulty hub/switch/router device.
3. An end station may have a faulty network interface card.
4. A protocol analyzer has been transmitting error packets.
__________________________________________________________________
Recommended Action(s):
1. Find out the source device and fix the problem.
Summary of Contents for Surveyor
Page 1: ...Surveyor User s Guide ...
Page 30: ...1 10 Surveyor User s Guide ...
Page 40: ...2 10 Surveyor User s Guide ...
Page 88: ...4 28 Surveyor User s Guide ...
Page 184: ...8 16 Surveyor User s Guide ...
Page 204: ...9 20 Surveyor User s Guide ...
Page 207: ...10 3 Expert Features Getting Started with Expert View10 Figure 10 1 Expert Overview Example ...
Page 211: ...10 7 Expert Features Expert Layers 10 Figure 10 3 Expert Application Layer Example ...
Page 368: ...11 34 Surveyor User s Guide ...
Page 390: ...13 12 Surveyor User s Guide ...
Page 416: ...C 4 Surveyor User s Guide ...
Page 426: ...D 10 Surveyor User s Guide ...
Page 454: ...Index 14 Surveyor User s Guide ...