10-108
Surveyor
User’s Guide
Excessive Collisions
Counter
Excessive Collisions is a counter that can be used to monitor fluctuations in the
number of collisions or the absolute number of collisions over a period of time per
segment. A delta threshold for this counter can be set in Expert Alarms to establish
what is considered excessive collisions. An alarm event can also be generated based
on an absolute number of collisions over time.
The Excessive Collision counter is incremented by counting runt packets and by
counting packets with CRC errors. The Excessive Collisions counter only applies to
Ethernet networks.
Summary of Contents for Surveyor
Page 1: ...Surveyor User s Guide ...
Page 30: ...1 10 Surveyor User s Guide ...
Page 40: ...2 10 Surveyor User s Guide ...
Page 88: ...4 28 Surveyor User s Guide ...
Page 184: ...8 16 Surveyor User s Guide ...
Page 204: ...9 20 Surveyor User s Guide ...
Page 207: ...10 3 Expert Features Getting Started with Expert View10 Figure 10 1 Expert Overview Example ...
Page 211: ...10 7 Expert Features Expert Layers 10 Figure 10 3 Expert Application Layer Example ...
Page 368: ...11 34 Surveyor User s Guide ...
Page 390: ...13 12 Surveyor User s Guide ...
Page 416: ...C 4 Surveyor User s Guide ...
Page 426: ...D 10 Surveyor User s Guide ...
Page 454: ...Index 14 Surveyor User s Guide ...