10-115
Expert Features
MAC Layer
10
Oversized Frame
Counter
The Oversize Frame counter increments when a frame has a CRC error and is
greater than 1518 bytes in length. A count of all Oversize Frames is included in the
Bad Frames counter that displays in the Overview counters of Expert View. The
Oversize Frame counter is used for Expert Alarms.
Expert Symptom
Oversized Frame events are automatically logged as expert symptoms. The
Symptom Summary
field contains the following information:
Oversized frame has more than 1518 bytes
Diagnostic Details
__________________________________________________________________
Problem Description:
A packet with more than 1518 bytes of data has been received.
__________________________________________________________________
Probable Cause(s):
1. A faulty hub/switch/router device.
2. An end station may have a faulty network interface card.
3. A protocol analyzer has been transmitting error packets.
__________________________________________________________________
Recommended Action(s):
1. Find out the source device and fix the problem.
Summary of Contents for Surveyor
Page 1: ...Surveyor User s Guide ...
Page 30: ...1 10 Surveyor User s Guide ...
Page 40: ...2 10 Surveyor User s Guide ...
Page 88: ...4 28 Surveyor User s Guide ...
Page 184: ...8 16 Surveyor User s Guide ...
Page 204: ...9 20 Surveyor User s Guide ...
Page 207: ...10 3 Expert Features Getting Started with Expert View10 Figure 10 1 Expert Overview Example ...
Page 211: ...10 7 Expert Features Expert Layers 10 Figure 10 3 Expert Application Layer Example ...
Page 368: ...11 34 Surveyor User s Guide ...
Page 390: ...13 12 Surveyor User s Guide ...
Page 416: ...C 4 Surveyor User s Guide ...
Page 426: ...D 10 Surveyor User s Guide ...
Page 454: ...Index 14 Surveyor User s Guide ...