Festo — MSE6-C2M — 2022-08b
Functions
43
Available selectable individual data
Input address
Selected input data
Low byte and/or high byte
Address value in output word Am.1
Input word Em.5 or Em.6
decimal
hexadecimal
Value
Description
0
0x00
Pressure change P2
Pressure change DP2
during the parameter-
ised pressure change
sample time
1
0x01
Fixed value 0
Reserved
2
0x02
Consumption V0
Consumption measure-
ment value V0 with 16-
bit limit
3
0x03
Consumption V1
Consumption measure-
ment value V1 with 16-
bit limit
4
0x04
Module time of opera-
tion
Module time of opera-
tion with 16-bit limit
5
0x05
Shut-off valve
switching cycles
Shut-off valve cycles
with 16-bit limitation
6
0x06
Current module error
Current module error,
only errors for which
monitoring is activated
and are reported:
Low byte, 8 bits:
Error number
High byte, 8 bit:
Error channel
1)
,Em.x,
Am.x continuous
7
0x07
All module errors
All module errors, inde-
pendent of parameter-
ised activation:
Low byte, 8 bits:
Error number high byte,
8 bit:
Error channel
1)
,Em.x,
Am.x continuous
1) Error channel specification in consecutive counting: 0 … 6: Em.0 … Em6.; 7 … 9: Am.0 … Am.2
Tab. 22: Available selectable individual data