10
Festo — MSE6-C2M — 2022-08b
Product overview
Electrical system extension with CPX I/O modules
The following CPX I/O modules are approved for extension:
–
CPX-4DE, 4 digital inputs
–
CPX-8DE, 8 digital inputs
–
CPX-4DA, 4 digital outputs
–
CPX-8DA, 8 digital outputs
–
CPX-8DE/8DA, 8 digital inputs and 8 digital outputs
–
CPX-4AE-U-I, 4 analogue inputs
–
CPX-2AA-U-I, 2 analogue outputs
A system extension with electrical outputs requires a CPX interlinking block with infeed because the
load voltage is not forwarded via a CPX-Extension.
The figure below shows the communication paths for a system extension with CPX I/O modules:
1
2
3
4
5
Fig. 3: System configuration with MSE6-C2M-...-M and 3 CPX I/O modules, maximum configuration
1
Controller board or network scanner/bus
master
2
User program in the machine controller
3
Network-specific configurator
4
Energy efficiency module MSE6-C2M-...-M
5
CPX I/O modules with CPX-Extension series
2 connection