68
Festo — MSE6-C2M — 2022-08b
Parameterisation
Function number
Changeable module parame-
ters
Function
m = module
number 0
Q
V
P2
DP2
REG
DI
DO
4828
+ m * 64 + 0
Pm.0: monitoring
Bit 0: SCS, short-circuit/over-
load in sensor supply
–
–
–
–
–
n
–
Bit 1: SCO, short circuit/over-
load at outputs
–
–
–
–
–
–
n
Bit 2: undervoltage U
Out/A
–
–
–
–
n
–
n
Bit 6: limit values
n
–
n
n
–
–
–
Bit 7: parameters
n
n
n
n
n
–
–
4828
+ m * 64 + 7
Pm.7: limit value startup
n
–
n
–
–
–
–
4828
+ m * 64 + 8
Pm.8: units
Bit 0 … 1: pressure
–
–
n
n
n
–
–
Bit 2 … 3: flow rate
n
–
–
–
n
–
–
Bit 4 … 5: consumption
–
n
–
–
–
–
–
Bit 6 … 7: flow rate standard
n
n
–
–
n
–
–
4828
+ m * 64 + 9
Pm.9: energy-save functions, are not currently supported
Bit 0: energy-save function
DO0
–
–
–
–
–
–
–
Bit 1: energy-save function
DO1
–
–
–
–
–
–
–
Bit 2: energy-save function
24VS
–
–
–
–
–
–
–
Bit 3: energy-save function
status LEDs
–
–
–
–
–
–
–
Bit 4: energy-save function
display
–
–
–
–
–
–
–
4828
+ m * 64 + 10
Pm.10: pressure change
sample time
–
–
–
n
–
–
–
4828
+ m * 64 + 11 … 12
Pm.11 … 12: flow rate, upper
limit value
n
–
–
–
–
–
–
4828
+ m * 64 + 13 … 14
Pm.13 … 14: upper limit value
pressure
–
–
n
–
–
–
–