Parameterisation
75
Module parameter: unit flow standard
Function number
4828 + m * 64 + 8
m = module number 0
Description
Sets the flow rate standard for all flow-related and consumption-related data.
Bit
Bit 6, 7: flow rate standard
All other bits are reserved.
Bit
7 6
Value
Meaning
0 0
0
DIN 1343, default
0 1
1
ISO 2533
1 0
2
ISO 6358
1 1
3
Not permissible
Comment
If parameter monitoring is active, Pm.0.7, invalid values will result in parameter-
isation error FN29
When the unit flow rate standard module parameter is changed, the values of
other module parameters related to the flow rate remain unchanged and are not
adjusted automatically.
Tab. 55: Flow rate standard module parameter
Module parameter: energy-save functions
Function number
4828 + m * 64 + 9
m = module number 0
Description
Defines the setting for all energy-save functions. This parameter is reserved
for later products models and is not supported in current products. Settings of
values have no effect on the behaviour of the module.
Bit
Description
0
Energy-save function DO0
1
Energy-save function DO1
2
Energy-save function 24VS
3
Energy-save function status LEDs
4
Energy-save function display
Values
0 = inactive (default)
1 = active
Comment
Parameter is not currently supported. The parameter may appear in software
tools for product parameterisation.
Tab. 56: Energy-save functions module parameters