74
Festo — MSE6-C2M — 2022-08b
Parameterisation
Module parameter: unit flow rate
Function number
4828 + m * 64 + 8
m = module number 0
Description
Specifies the unit for all flow-related data.
Bit
Bit 2, 3: unit flow rate
All other bits are reserved.
Bit
3 2
Value
Meaning
0 0
0
l/min, default
0 1
1
Not permissible
1 0
2
scfm/10
1 1
3
Not permissible
Comment
If parameter monitoring is active, Pm.0.7, invalid values will result in parameter-
isation error FN29
When the unit flow rate module parameter is changed, the values of other
flow-related module parameters remain unchanged and are not adjusted auto-
matically.
Tab. 53: Unit flow rate module parameter
Module parameter: unit consumption
Function number
4828 + m * 64 + 8
m = module number 0
Description
Specifies the unit for all consumption-related data.
Bit
Bit 4, 5: unit consumption
All other bits are reserved.
Bit
5 4
Value
Meaning
0 0
0
l, default
0 1
1
m³
1 0
2
scf
1 1
3
Not permissible
Comment
If parameter monitoring is active, Pm.0.7, invalid values will result in parameter-
isation error FN29
Tab. 54: Unit consumption module parameter