Festo — MSE6-C2M — 2022-08b
Functions
25
5.1.5.4
Functional states
The current functional state is displayed in the input module state, Em.3.6-3.9.
The table shows an overview of the possible functional states in all operating modes.
Em.3.8-3.11
Module
status
Functional status
Functional
mode
Meaning
0
USER_RISE
USER
Pressure increase until the target pressure set
by the user is reached
1
USER_PON
USER
Pressure regulation to set power-on setpoint
pressure
2
USER_MIN
USER
Pressure regulation at minimum setpoint pres-
sure, 0.25 MPa (2.5 bar; 36.3 psi)
3
USER_REGOFF
USER
Electronic pressure regulation is deactivated
4
USER_VAR
USER
Pressure regulation to set setpoint pressure
according to Am.2
5
USER_SHUTOFF
USER_
Module in blocking status
7
OFF_24VA
USER/AUTO
No load voltage supply;
Pressure control and blocking function not
active
8
AUTO_NORMAL
AUTO
Pressure regulation at parameterised auto
normal setpoint pressure
9
AUTO_WAIT
AUTO
Pressure regulation at parameterised auto
normal setpoint pressure, Q_low-Timer expired,
automatic pressure regulation and blocking
function not activated
10
AUTO_HOLD
AUTO
Pressure regulation at parameterised auto
normal setpoint pressure, Q_low-Timer expired,
automatic pressure regulation and blocking
function not activated
11
AUTO_SHUTOFF
AUTO
Module in blocking status, Q_low-Timer expired,
automatic pressure regulation and blocking
function activated
12
AUTO_STANDBY
AUTO
Pressure regulation at parameterised auto
standby setpoint pressure
13
AUTO_RISE
AUTO
Pressure increase up to the parameterised auto
normal setpoint pressure
Tab. 6: Possible functional states in all operating modes