Festo — MSE6-C2M — 2022-08b
Parameterisation
85
Module parameter: setpoint pressure rise limitation
Function number
4828 + m * 64 + 28
m = module number 0
Description
The parameter defines the slope as the setpoint pressure increases. The limi-
tation is effective for both automatic and user-controlled operation, including
power-on. The set rise limitation also applies when the operating mode is
changed.
Bit
Bit 4 … 6
Bit
6 5 4
Value
0 0 0
0 = OFF, default
–
0 0 1
1 = 10 bar/s
1000 kPa/s; 145.04 psi/s
0 1 0
2 = 5 bar/s
500 kPa/s; 72.52 psi/s
0 1 1
3 = 2.5 bar/s
250 kPa/s; 36.3 psi/s
1 0 0
4 = 1 bar/s
100 kPa/s; 14.50 psi/s
1 0 1
5 = 0.5 bar/s
50 kPa/s; 7.25 psi/s
1 1 0
6 = 0.25 bar/s
25 kPa/s; 3.63 psi/s
1 1 1
7 = 0.125 bar/s
12.5 kPa/s; 1.81 psi/s
Com-
ment
The setpoint pressure can deviate up to 15% from the ideal value during the
target pressure increase.
The parameter value is permanently stored in the module and is the valid value
for the next power-on. A change of the parameter value is effective immediately.
Tab. 75: Setpoint pressure rise limitation module parameter
Module parameter: user measure select
Function number
4828 + m * 64 + 28
m = module number 0
Description
Defines the setting for all measuring functions. This parameter is reserved for
later products models and is not supported in current products. Settings of
values have no effect on the behaviour of the module.
Bit
Bit 7
Values
0 = controller with Am.0.8-9, default
1 = controller with DI1
Comment
Parameter is not currently supported. The parameter may appear in software
tools for product parameterisation.
Tab. 76: User measure select module parameter