DNCE
28
Festo – DNCE – 1109e English
11
Troubleshooting
Malfunction
Possible cause
Remedy
Backlash too
great
(
8 Mainten-
ance and care)
Wear
Send DNCE to Festo for repair
Squeaking
noises or
vibrations
Distortions
Mount DNCE free of stress
(evenness of bearing surface: ≤ 0.2 mm)
Lubricate piston rod
(
8 Maintenance and care)
Modify speed of travel
Incorrect regulator settings
Modify the regulator parameters
(only with servo motors)
Running noises of the spindle support
(with strokes ≥ 300 mm and high posi-
tioning speeds)
No impairment of function
Piston rod
does not move
Jamming in the mechanical end position
(e. g. after reference travel with excess-
ive speed or prohibited travel to the end
position during operation)
–
To release a jam manually:
1. Switch off the power supply,
2. Remove motor and coupling
housing,
3. Turn drive shaft to release it
–
Reduce speed for reference travel
–
Provide software end positions, at
least 0.25 mm away from the
mechanical end positions (stops)
Loads too high
–
Reduce load mass
–
Reduce travel speed
–
Send DNCE to Festo for repair
Tension of toothed belt in parallel kit
too high
Reduce tension of toothed belt
(
Parallel kit assembly instructions)
Ambient temperature too low
(increased breakaway torque in initial
run due to increasing viscosity of the
lubricants in the spindle system)
–
Reduce load mass
–
Reduce travel speed
–
If necessary, allow higher current
with servo motors (
Operating
instructions for the motor)
–
Adjust ambient temperature