4. Commissioning
4-23
Festo P.BE-DLP-VSE-... en 0206a
Further octets
Octet
Designation
Explanation
2 and 3
WD_Fact_1
WD_Fact_2
Range 1-255: the response monitoring time of the
Local control unit is transmitted with these two
octets:TWD [s] = 10ms * WD_Fact_1 * WD_Fact_2
4
Minimum station delay re-
sponder (min TSDR)
The minimum time the Local control unit must wait
before the reply telegram may be sent to the DP
master.
5 and 6
Ident_Number
Transmitting the Ident number (= 045B) of the Local
control unit;
Parametrizing telegrams to the Local control unit are
only accepted if the transferred Ident number and the
programmed Ident number are the same.
7
Group_Ident
Not supported by the Local control unit
8 ... 32
User_Prm_Data
Not supported by the Local control unit
Sending configuration data
The configuration data are transmitted from the DP master to
the Local control unit with the function
Chk_Cfg
.
Summary of parameters (Chk_Cfg
)
:
Octet 1-n
DP identifier
Permitted identifiers for Festo CP systems
in compact mode.
Number of inputs/
outputs
DP identifier
decimal
hex
Comment
4
Octet 1 8DX
Octet 1 30
4 digital inputs and outputs
1 analogue
Octet 2 1AE
Octet 2 50
analogue measured value
Summary of Contents for DLP-VSE Series
Page 1: ...Manual Local control unit DLP VSE DLP VSE DP DLP VSE ASI Manual 396 535 en 0206a...
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE DLP VSE en 0206a...
Page 8: ...Contents and general instructions VI Festo P BE DLP VSE en 0206a...
Page 20: ...1 Summary of components 1 8 Festo P BE DLP VSE en 0206a...
Page 54: ...3 Installation 3 30 Festo P BE DLP VSE en 0206a...
Page 84: ...4 Commissioning 4 30 Festo P BE DLP VSE en 0206a...
Page 104: ...5 Diagnosis 5 20 Festo P BE DLP VSE en 0206a...
Page 108: ...A Technical specifications and index A 4 Festo P BE DLP VSE en 0206a...